1
Power entry modules without line filter
1062
www.schurter.com/pg05
Connectors
IEC Appliance Inlet C14 or C18 with Fuseholder 1- or 2-pole
1062: Design 1 + 2
equipment class 1
1062: design 6 + 7
equipment class 1
C14
70° C
C18
70° C
Description
- Panel Mount:
Screw-on from front side, Appliance Inlet, protection class I or II, Fuse-
holder for fuse-links 5 x 20 mm
- Solder terminals or quick connect terminals
Approvals
- UL File Number: E93617
- CSA File Number: 27324
Characteristics
- The fuse drawer “Fingergrip” can be removed by hand
The fuseholder is accessible from the equipment front
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, Mating Connectors,
e-Shop, SCHURTER-Stock-Check, Distributor-Stock-Check, CAD-
Drawings, Accessories, Detailed request for product
Technical Data
Ratings IEC 10 A / 250 VAC; 50 Hz
Ratings UL/CSA 10 A / 250 VAC; 60 Hz
Dielectric Strength > 3 kVAC between L-N
> 1.5 kVAC between L/N-PE
(1 min/50 Hz)
Allowable Operation Temp. -25 °C to 70 °C
Degree of Protection from front side IP 20 acc. to IEC 60529
Protection Class Suitable for appliances with protection
class I or II acc. to IEC 61140
Terminal Solder terminals or quick connect ter-
minals
Material: Housing PA6, black / grey / white, UL 94V-0
Appliance Inlet C14 / C18 acc. to IEC 60320
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I or II
Fuseholder 1 or 2 pole, acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
Power Acceptance @ Ta >
23°C
Admissible power acceptance at hig-
her ambient temperature see derating
curves
Dimensions
371.2
50
40
33
28
16.5 5
3
19.7
ø 3.2
33
31
R 0.5
R 0.5
33.2
+0.2
- 0
33.2
+0.2
- 0
40
R <2
Length of the terminal please find at the order code configuration table