S
–5–
ASCTB207E 201701-T
DIMENSIONS (mm inch)
SAFETY STANDARDS
NOTES
UL/C-UL (Recognized) CSA (Certified)
File No. Contact rating File No. Contact rating
E43028
4A 250V AC
LR26550
4A 250V AC
3A 30V DC 3A 30V DC
1/20HP 250V AC (FLA0.75A) 1/20HP 250V AC
1/20HP 125V AC (FLA1.5A) 1/20HP 125V AC
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
General tolerance: ±0.3 ±.012
PC board pattern (Copper-side view)
Tolerance: ±0.1 ±.004
10±0.5
12
7.62
123456
12 11 10 9 8 7
3
1
4
0.4
1.4
1.0
5.08
0.5
0.5
7.62
28±0.5
12
.118
.394±0.02
.472
.300
.039
.157
.016
.055
.039
.200
.020
.020
.300
1.102±0.02 .472
2.54
2.54
12-1.3 dia.
.100
.100
.047-.051 dia.
Schematic (Bottom view)
Single side stable
(Deenergized position)
2 coil latching
(Reset condition)
2a2b
3a1b
4a
123456
12 11 10 9 8 7
-
+
123456
12 11 10 9 8 7
-
+
-
+
123456
12 11 10 9 8 7
-
+
-
+
123456
12 11 10 9 8 7
-
+
123456
12 11 10 9 8 7
-
+
-
+
123456
12 11 10 9 8 7
-
+
CAD Data
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.
2. Based on regulations regarding
insulation distance, there is a
restriction on same-channel load
connections between terminals No. 2,
3 and 4, 5, as well as between No. 8, 9
and 10, 11. See the figure below for an
example.
3. Please note that when this relay
(2 Form A 2 Form B type, 3 Form A
1 Form B type) operates and releases,
contacts a and b may go ON at the
same time.
4
2
5
3
10
9
4
8
11
5
23
9
8
11
10
•
•
Between 2, 3 and 4, 5:
different channels, therefore not possible
Between 10, 11 and 8, 9:
different channels, therefore not possible
•
•
Between 2, 3 and 4, 5:
same channels, therefore possible
Between 10, 11 and 8, 9:
same channels, therefore possible
No good Good