Universally configurable temperature limit value switch with two transistor outputs for the connection of 2, 3,
and 4-conductor resistance thermometers and thermocouples. Configurable via DIP switch or software, push-
in connection technology
Product Description
Universally configurable temperature limit value switch with two transistor outputs for the connection of 2, 3, and 4-conductor resistance
thermometers and thermocouples. You can configure the device using one of the free software solutions available or your smartphone. Default
settings can also be made directly on the device by simply using the DIP switches (see configuration table). The temperature limit value switch
supports fault monitoring and NFC communication.
Key Commercial Data
Packing unit 1 STK
GTIN
GTIN 4055626131566
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width 6.2 mm
Height 110.5 mm
Depth 120.5 mm
Ambient conditions
Ambient temperature (operation) -40 °C ... 70 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Input data
Number of inputs 1
https://www.phoenixcontact.com/pi/products/2906877
08/19/2018Page2/5
Limit value switches-MINI MCR-2-T-2RO-PT-2906877
Technical data
Input data
Available input sources Resistance thermometers
Sensor types (RTD) that can be used Pt, Ni, Cu sensors
Connection technology 2, 3, 4-wire
Sensor input current approx. 200 µA
Max. permissible overall conductor resistance ≤ 25 Ω (Per line, RTD in 3- or 4-wire technology)
≤ 50 Ω (Per line, RTD in 2-wire technology)
Linear resistance measuring range 0 Ω ... 4000 Ω
Linear mV signal range -500 mV ... 500 mV
Available input sources Thermocouples
Sensor types that can be used (TC) B, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M, L
Switching output
Output name Switching output
Number of outputs 2
Contact type 2 N/O contacts
Maximum switching voltage 30 V DC
Max. switching current 100 mA (30V (≤ 50°C))
70 mA (30V (51°C...70°C))
Power supply
Nominal supply voltage 24 V DC
Supply voltage range
9.6 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2
1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the
supply voltage. It can be snapped onto a 35 mm DIN rail according to
EN60715))
Typical current consumption 20 mA (12 V DC)
10 mA (24 V DC)
Power consumption 350 mW
Connection data
Connection method Push-in connection
Single conductor/terminal point, solid, with ferrule, min. 0.14 mm²
Single conductor/terminal point, solid, with ferrule, max. 2.5 mm²
Single conductor/terminal point, solid, without ferrule, min. 0.14 mm²
Single conductor/terminal point, solid, without ferrule, max. 2.5 mm²
Conductor cross section flexible min. 0.14 mm²
Conductor cross section flexible max. 2.5 mm²
Min. AWG conductor cross section, flexible 24
Max. AWG conductor cross section, flexible 12
Stripping length 10 mm
General
No. of channels 1
Maximum temperature coefficient 0.01 %/K
https://www.phoenixcontact.com/pi/products/2906877
08/19/2018Page3/5
Limit value switches-MINI MCR-2-T-2RO-PT-2906877
Technical data
General
Switching point accuracy < 0.1 %
Status display Yellow LED (switching output)
Electrical isolation Reinforced insulation in accordance with IEC 61010-1
Overvoltage category II
Degree of pollution 2
Rated insulation voltage 300 V
Test voltage, input/output/supply 3 kV (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity
EN 61000-6-2 When being exposed to interference, there may be
minimal deviations.
Color gray
Housing material PBT
Mounting position any
Assembly instructions
The T connector can be used to bridge the supply voltage. It can be
snapped onto a 35 mm DIN rail according to EN 60715.
Conformance CE-compliant
ATEX  II 3 G Ex nA IIC T4 Gc X
UL, USA/Canada UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
GL GL applied for
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2
Standards and Regulations
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Electrical isolation Reinforced insulation in accordance with IEC 61010-1
Conformance CE-compliant
ATEX  II 3 G Ex nA IIC T4 Gc X
UL, USA/Canada UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T6
Class I, Zone 2, Group IIC T6
GL GL applied for
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2
Environmental Product Compliance

2906877

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Terminal Block Interface Modules MINI MCR-2-T-2RO-PT
Lifecycle:
New from this manufacturer.