*Load increase reduces life
expectancy of Reed Switches
A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet – HF Reed Relays
www.standexmeder.com
Form
A
NO = Normally Open Contacts
SPST = Single Pole Single
Throw
Contacts
= Single Pole Single Throw
SPDT = Single Pole Double
Throw
Data Unit
1/2 sine wave duration 11ms
50 g
Resistance (max.)
20 g
-40 to 85 °C
-40 to 105 °C
Temperature (max.)
260 °C
& Assembly Instructions
Switching inductive and/or capacitive loads create voltage
and/or current peaks, which may damage the relay.
Protective circuits need to be used.
External magnetic fields needs to be taken into
consideration, including a too high packing density. This may
influence the relays’ electrical characteristics.
Mechanical shock impacts e.g. dropping the relays may cause
immediate or post-installation failure.
Wave soldering: maximum 260°/5 seconds.
Reflow soldering: Recommendations given by the soldering
paste manufacturer need to be considered as well as the
temperature limits of other components/processes.
Modifications in the sense of technical progress are reserved.
Version 01
27.01.2015
USA: +1.866.782.6339 │ salesusa@standexmeder.com
Europe: +49.7731.8399.0 │ info@standexmeder.com
Asia: +86.21.37820625 │ salesasia@standexmeder.com
Coil Data
Coil Voltage
(nom.)
Coil Resistance
(typ.)
Pull-In Voltage
(max.)
Drop-Out Voltage
(min.)
(typ.)
Form
Model
Unit VDC Ohm VDC VDC mW
1A
54
05 40 3.5 0.75 625
12 250 8.4 1.8 575
24 1,000 16.8 3.6 575
1B*
05 30 3.5 0.75 835
12 170 8.4 1.8 850
24 680 16.8 3.6 850
-In / Drop-Out Voltage and Coil Resistance will change at rate of 0.4% per °C.
Re-closure of Form B may occur if the max. coil voltage is exceeded. Coil polarity on Form B must be observed. Pin 2 is positive.