2
Technical Data 10629
Effective December 2016
FP1008R7
High frequency, high current power inductors
www.eaton.com/electronics
Product specifications
Part Number
8
OCL
1
(nH) ±10%
FLL
2
(nH) minimum
I
rms
3
(A)
I
sat
1
4
(A)
I
sat
2
5
(A)
I
sat
3
6
(A)
DCR (mΩ)
maximum @ 20°C K-factor
7
FP1008R7-R100-R 100 72 72 100 90 84 0.120 361
FP1008R7-R120-R 120 86 72 90 75 70 0.120 361
FP1008R7-R150-R 150 108 72 72 60 56 0.120 361
FP1008R7-R180-R 180 130 72 60 50 46 0.120 361
1. Open Circuit Inductance (OCL) Test Parameters: 100 kHz, 0.1 Vrms, 0.0 Adc, +25 °C
2. Full Load Inductance (FLL) Test Parameters: 100 kHz, 0.1 Vrms, I
sat
1, +25 °C
3. I
rms
: DC current for an approximate temperature rise of 40 °C without core loss. Derating is
necessary for AC currents. PCB layout, trace thickness and width, air-flow, and proximity of
other heat generating components will affect the temperature rise. It is recommended that the
temperature of the part not exceed 125 °C under worst case operating conditions verified in the
end application.
4. I
sat
1: Peak current for approximately 20% rolloff @ +25 °C
5. I
sat
2: Peak current for approximately 20% rolloff @ +100 °C
6. I
sat
3: Peak current for approximately 20% rolloff @ +125 °C
7. K-factor: Used to determine B
p-p
for core loss (see graph).
B
p-p
= K * L * ∆I * 10
-3
. B
p-p
:(Gauss), K: (K-factor from table),
L: (Inductance in nH), ∆I (Peak to peak ripple current in Amps).
8. Part Number Definition: FP1008R7-Rxxx-R
FP1008R7= Product code and size
x= Version indicator
Rxxx= Inductance value in μH, R= decimal point
-R suffix = RoHS compliant
Dimensions (mm)
Part marking: FP1008R7, Rxxx (xxx=inductance value in uH, R=decimal point),
xxxx=Lot code
Tolerances are ±0.15 millimeters unless stated otherwise.
All soldering surfaces to be coplanar within 0.1 millimeters
Pad layout tolerances are ±0.1 millimeters unless stated otherwise
DCR measured from point “a” to point “b”
Do not route traces or vias underneath the inductor