7741 North Business Park Drive
Tucson, Arizona 85743
Ph: 520-744-0400 Fax: 520-744-6155
Web site: www.tusonix.com E-mail: sales@tusonix.com
General Test Specifications
The Components shown in this catalog have been designed and subjected to the following test
plan, as is applicable for the individual components. The information shown can be used as a
basis for component specifications. For additional information, please consult Customer Engi-
neering at (520) 744-0400.
Filters governed by MIL-PRF-15733 shall be inspected and tested to the requirements of the
specification and the applicable specification (slash) sheet.
PERIODIC QUALITY CONFORMANCE INSPECTION:
A periodic quality conformance inspection program consisting of environmental and reliability
testing is in place to ensure that product integrity is consistently maintained.
TUSONIX on-line www.tusonix.com
The TUSONIX Web site provides visitors with a wide range of product and ordering information.
At www.tusonix.com, customers can view product information and download catalogs in Adobe
Acrobat
®
.pdf format. Customers can also view or link to Sales Offices, International Agents and
Distributors. An on-line request form allows customers to immediately specify product require-
ments and request product information.
26
LOT ACCEPTANCE INSPECTION:
INSPECTION OR TEST
TEST METHOD PER MIL-STD-202
EXCEPT AS NOTED
POST TEST REQUIREMENTS
Visual and Mechanical
Materials, Design, Construction
and Workmanship
Physical Dimensions & Marking
Seal (4601 Style Only)
Capacitance
Dissipation Factor (1/Q)
Dielectric Withstanding Voltage
Insulation Resistance
Insertion Loss
DC Resistance (4601 Style Only)
Solderability (5pcs)
In accordance with applicable
requirements
Method 301, 2 seconds, 50 mA max. surge
current, 2 times WVDC.
Method 112, condition A
Method 305, 1KHz, 1±0.2 VRMS max. +25°C
Method 306, 1KHz, 1±0.2 VRMS max. +25°C
Method 302, 50 mA max. charging current,
100VDC, 2 minutes or as specified by
individual variation
MIL-STD-220, 50 Ohms, +25°C, no load
MIL-PRF-15733
Method 208
No leaks
Within specified tolerance
4.0% max
Greater than 10,000 Megohms
or 100 Ohm-Farads, whichever
is less.
Per application requirements.
0.01 Ohms max.
Per applicable requirements.
No evidence of damage or
break down.