SCHRACK
General Purpose Relays
PCB Relays
Power PCB Relay RZ
Contact ratings for RZ reinforced flux proof version
Type Contact Load Cycles
IEC 61810
RZ03-1C3-D...-R A (NO) 16A, 250VAC, 85°C 30x10
3
RZ03-1C3-D...-R C (CO) 16A, 250VAC, 85°C 6x10
3
RZ01-1C3-D...-R A (NO) 12A, 250VAC, 85°C 30x10
3
RZ01-1C3-D...-R C (CO) 12A, 250VAC, 85°C 6x10
3
RZ03-1C4-D...-R A (NO) 16A, 250VAC, 85°C 30x10
3
RZ03-1C4-D...-R C (CO) 16A, 250VAC, 85°C 6x10
3
RZ02/3-1C4-D...-R A (NO) 12A, 250VAC, 85°C 50x10
3
RZ02/3-1C4-D...-R C (CO) 12A, 250VAC, 85°C 20x10
3
UL 508
RZ03-1C3-D...-R A (NO) 16A, 277VAC, 85°C 30x10
3
RZ03-1C3-D...-R C (CO) 16A, 277VAC, 85°C 6x10
3
RZ01-1C3-D...-R A (NO) 12A, 277VAC, 85°C 30x10
3
RZ01-1C3-D...-R C (CO) 12A, 277VAC, 85°C 6x10
3
RZ03-1C4-D...-R A (NO) 16A, 277VAC, 85°C 30x10
3
RZ03-1C4-D...-R C (CO) 16A, 277VAC, 85°C 6x10
3
RZ02/3-1C4-D...-R A (NO) 12A, 277VAC, 85°C 50x10
3
RZ02/3-1C4-D...-R C (CO) 12A, 277VAC, 85°C 20x10
3
Mechanical endurance >10x10
6
operations
n
1 pole 12/16 A, 1 form C (CO) or 1 form A (NO) contact
n
DC coil 400 mW
n
5kV/10mm coil-contact, reinforced insulation
n
Ambient temperature 85°C
n
Product in accordance to IEC 60335-1
Typical applications
Household appliances, boiler control, timers, garage door control, POS
automation
Approvals
VDE Cert. No. 40023970, UL E214025, CQC 12002066685
Technical data of approved types on request
Contact Data 12A 16A
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage 250VAC
Max. switching voltage 400VAC
Rated current 12A 16A
Limiting making current (form A contact)
max. 4s, duty factor 10% 30A
max. 20ms (incandescent lamp); AgSnO
2
80A
Breaking capacity max. 3000VA 4000VA
Contact material AgNi 90/10 or AgSnO
2
Frequency of operation, with/without load 360/72000h
-1
Operate/release time max. 8/6ms
Bounce time max., form A/form B 4/10ms
Contact ratings for standard version
Type Contact Load Cycles
IEC 61810
RZ03-1A4 A (NO) 16A, 250VAC, 85°C 50x10
3
RZ03-1C4 C (CO) 16A, 250VAC, 85°C 10x10
3
RZ01-1A3 A (NO) 12A, 250VAC, 85°C 100x10
3
RZ01-1A4 A (NO) 12A, 250VAC, 85°C 50x10
3
RZ01-1C4 C (CO) 12A, 250VAC, 85°C 30x10
3
RZ01/3-1A4 A (NO) 10A, 250VAC, 85°C 150x10
3
RZ0H-1A4 A (NO) 12A, 250VAC, 85°C 150x10
3
RZ0H-1A4 A (NO) 16A, 250VAC, 85°C 50x10
3
RZ0H-1A4 A (NO) 18A, 250VAC, 85°C 30x10
3
UL 508
RZ03-1A. A (NO) 16A, 250VAC, 85°C 50x10
3
RZ03-1A4 A (NO) 12A, 250VAC, 85°C 150x10
3
RZ01-1A3 A (NO) 12A, 250VAC, 85°C 50x10
3
RZ03-1.4 A (NO) B300, R300, 85°C 6x10
3
RZ03-1.4 A (NO) 12A, 250VAC, 85°C 100x10
3
RZ03-1.4 A (NO) 1/2hp, 125VAC, 85°C 6x10
3
RZ03-1A. A (NO) 1hp, 277VAC, 85°C 30x10
3
F0305-A
1) valid for standard version
1)