Sensitive Triacs Data Sheets
http://www.littelfuse.com E1 - 4 ©2004 Littelfuse, Inc.
+1 972-580-7777 Thyristor Product Catalog
Specified Test Conditions
di/dt — Maximum rate-of-change of on-state current; I
GT
= 50 mA with
0.1
µs rise time
dv/dt — Critical rate-of-rise of off-state voltage at rated V
DRM
gate open
dv/dt(c) — Critical rate-of-rise of commutation voltage at rated V
DRM
and I
T(RMS)
commutating di/dt = 0.54 rated I
T(RMS)
/ms; gate
unenergized
I
2
t — RMS surge (non-repetitive) on-state current for period of 8.3 ms
for fusing
I
DRM
— Peak off-state current, gate open; V
DRM
= max rated value
I
GT
— DC gate trigger current in specific operating quadrants;
V
D
= 12 V dc; R
L
= 60 Ω
I
GTM
— Peak gate trigger current
I
H
— Holding current gate open; initial on-state current = 100 mA dc
I
T(RMS)
— RMS on-state current conduction angle of 360°
I
TSM
— Peak one-cycle surge
P
G(AV)
— Average gate power dissipation
P
GM
— Peak gate power dissipation; I
GT
≤ I
GTM
t
gt
— Gate controlled turn-on time; I
GT
= 50 mA with 0.1 µs rise time
V
DRM
— Repetitive peak off-state/blocking voltage
V
GT
— DC gate trigger voltage; V
D
= 12 V dc; R
L
= 60 Ω
V
TM
— Peak on-state voltage at max rated RMS current
General Notes
• All measurements are made with 60 Hz resistive load and at an
ambient temperature of +25 °C unless otherwise specified.
• Operating temperature range (T
J
) is -65 °C to +110 °C for TO-92
devices and -40 °C to +110 °C for all other devices.
• Storage temperature range (T
S
) is -65 °C to +150 °C for TO-92
devices, -40 °C to +150 °C for TO-202 devices, and -40 °C to
+125 °C for TO-220 devices.
• Lead solder temperature is a maximum of 230 °C for 10 seconds
maximum at a minimum of 1/16” (1.59 mm) from case.
• The case or lead temperature (T
C
or T
L
) is measured as shown on
dimensional outline drawings. See “Package Dimensions” section
of this catalog.
I
T(RMS)
Part No.
V
DRM
I
GT
I
DRM
Isolated Non-isolated
(11)
TO-220
TO-252
D-Pak
TO-251
V-Pak
(1)
Volts
(3) (6)
mAmps
(1) (14)
mAmps
QI QII QIII QIV T
C
= 25 °C T
C
= 110 °C
MAX See “Package Dimensions” section for variations. (12) MIN MAX MAX
6A
L2006L5 L2006D5 L2006V5 200 5555 0.02 0.5
L4006L5 L4006D5 L4006V5 400 5555 0.02 0.5
L6006L5 L6006D5 L6006V5 600 5555 0.02 0.5
L2006L6 L2006D6 L2006V6 200 5 5 5 10 0.02 0.5
L4006L6 L4006D6 L4006V6 400 5 5 5 10 0.02 0.5
L6006L6 L6006D6 L6006V6 600 5 5 5 10 0.02 0.5
L2006L8 L2006D8 L2006V8 200 10 10 10 20 0.02 0.5
L4006L8 L4006D8 L4006V8 400 10 10 10 20 0.02 0.5
L6006L8 L6006D8 L6006V8 600 10 10 10 20 0.02 0.5
8A
L2008L6 L2008D6 L2008V6 200 5 5 5 10 0.02 0.5
L4008L6 L4008D6 L4008V6 400 5 5 5 10 0.02 0.5
L6008L6 L6008D6 L6008V6 600 5 5 5 10 0.02 0.5
L2008L8 L2008D8 L2008V8 200 10 10 10 20 0.02 0.5
L4008L8 L4008D8 L4008V8 400 10 10 10 20 0.02 0.5
L6008L8 L6008D8 L6008V8 600 10 10 10 20 0.02 0.5
MT1
MT2
G
MT2
MT2
MT1
G
MT2
MT2
G
MT1