VS-M12MSD/ 5,0-93X OD Order No.: 1454215
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1454215
PHOENIX CONTACT Inc., USA Page 3 / 5
http://www.phoenixcon.com Jul 26, 2011
Nominal voltage, conductor 300 V
Test voltage, conductor 1500 V
Overall twist 4 wires, twisted
Shielding Plastic-coated aluminum foil, tinned copper braided shield
Optical shield covering 100 %
Outer sheath, material Radox GKW S
Material conductor insulation Radox Com
Conductor material silver-plated Cu litz wires
Cable weight 67 kg/km
Smallest bending radius, fixed installation > 43.5 mm
Ambient temperature (operation) -40 °C ... 90 °C (cable, fixed installation)
-25 °C ... 90 °C (cable, flexible installation)
Special properties Fire protection in rail vehicles as per DIN 5510-2 Fire protection
level 1, 2, 3, 4
Fire protection in rail vehicles as per BS 6853 Cables inside and
outside the vehicle, Cat. Ia, Ib, II
manufactured as per EN 50288-2-2 multi-strand metallic data and
control cables
Fire protection in rail vehicles according to CEI 11170
Resistance to oil as per EN 50306-3 section 4.8
Other resistance Resistance to acids and alkalis as per EN 50306-3 section 4.10
Resistance to fuels as per EN 50306-3 section 4.9
Accessories
Item Designation Description
Tools
1212513 SAC BIT M12-W14 SAC nut, for assembling M12 connectors with hexagonal high-
grade steel knurl, with 4 mm hexagonal drive
1208429 TSD 04 SAC Torque screwdriver, with preset torque of 0.4 Nm and 4 mm
hexagonal drive for M12 connectors