EMC Filtering - Suggestion for EN55022 Class B (Conducted and Emitted)
XX.X± 0.5 mm
XX.XX± 0.25 mm
R1S_R1D
Series
R1S-R1D
R1S** :** with marking 12 denotes 10 pins out of 12 fitted (includes /H option)e.g. R1S12-0505, R1S12-0505/H, R1S12-0505/HP
R1D** : ** with marking 12 denotes 10 pins out of 12 fitted (includes /H option)e.g. R1D12-0505, R1D12-0505/H, R1D12-0505/HP
+
Fuse
Output
C1
Input
470pF/4kVDC
L1
DC
DC
+
Fuse
+Vout
C1
Input
470pF/4kVDC
L1
-Vout
Com
DC
DC
Standard and /H versions
C1L1Vin
4.7µF3.3µH3.3V
2.2µF4.7µH5V
2.2µF10µH12V
2.2µF22µH15V
4.7µF22µH24V
/P and /HP versions
C1L1Vin
4.7µF10µH3.3V
10µF10µH5V
4.7µF22µH12V
4.7µF22µH15V
10µF47µH24V
C1 = MLCC
L1 = SMD Inductor
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer