NBM-10-331-D

NB-4
NBM series
Low leakage current type, Withstand voltage 4,000VAC (2-stage filter)
NBM -10 -471 -O
Ordering information
1 Model Name
2 Rated Current
3 Line to ground capacitor code:See table 1.1.
table1.1 Line to ground capacitor code
Code
Leakage Current
(Input 125/250V 60Hz)
Line to ground
capacitor
(nominal value)
000
5
A
/
10
A
max
Not Provided
101 12.5
A/ 25 A max 100pF
221 25
A/ 50 A max 220pF
331 37.5
A/ 75 A max 330pF
471
50
A
/
100
A
max
470pF
*
When the line to ground capacitor code is
different, the attenuation characteristic is
different.
4 Options
D
:DIN rail installation type
*
The dimensions change when the option is set.
Refer to External view.
1 2 3 4
Features of NBM series
Circuit Diagram Derating Curve
LI
NE
Case
: Mounting Plate
1
2
4
3
CY
CY
CY : Line to ground capacitor
LOAD
L
I
I
N
N
E
E
as
Case
: Mounting Plat
e
: Mounting Plate
1
1
2
2
4
4
3
3
C
C
Y
Y
C
C
Y
Y
C
C
Y
Y
Y
: Line to ground capacito
r
: Line to ground capacitor
L
L
O
O
A
A
D
D
Low leakage current type, Withstand voltage 4,000VAC (2-stage filter)
- Single Phase 250 VAC
- Push down type terminal block
R
9050 60 70 80
20
0
-4040-30-20
100
80
60
40
55
Ambient Temperature [C]
Load Factor [%]
Specifications
No. Items NBM-06-471 NBM-10-471 NBM-16-471 NBM-20-471 NBM-30-471
1 Rated Voltage[V] AC 1
f
250 / DC250
2 Rated Current[A] 6 10 16 20 30
3 Test Voltage (Terminal-Mounting Plate) 4,000 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
4 Isolation Resistance (Terminal-Mounting Plate) 500 VDC 100M
W
min at room temperature and humidity
5 Leakage current 125/250V 60Hz 50
A/100 A max
6 Voltage drop 1.0V max
7 Safety agency approval temperatures -25 to +85
C
(Refer to Derating Curve)
8 Operating temperature -40 to +85
C
(Refer to Derating Curve)
9 Operating humidity 20 to 95%RH (Non condensing)
10 Storage temperature/humidity -40 to +85
C
/20 to 95%RH (Non condensing)
11 Vibration 10 to 55Hz, 19.6m/s
2
(2G), 3min. Period, 1hour each X, Y and Z axis
12 Impact 196.1m/s
2
(20G), 11ms Once each X, Y and Z axis
13 Safety agency approvals UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
14 Case size (without projection) /Weight
53
X
41
X
92 mm [2.09
X
1.61
X
3.62 inches] (W
X
H
X
D) /270g max (Option : -D refer to external view)
DIN rail installation type is option The terminal cover is retracted inside the unit
NB-5
NBC,NBM series
12
92
82
45
80
15
[0.59]
[2.09]
[1.77]
[0.47]
[1.61]
[0.08]
53
2
41
2.5
8
30.5
Mounting Plate
Terminal cover
2-Protection Earth
6-M4
2-f4.8
[0.19]
[3.15]
[3.62]
[0.1][1.2]
[0.31]
[3.23]
Tolerance : ±1 [±0.04]
Weight : 270g max
Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04]
Case : PBT
Dimensions in mm, [ ]=inches
Terminal block screw tightening torque M4:1.6N-m (16.9kgf-cm) max
Output
Terminal
Input
Terminal
Output
Terminal
Mounting Hole
Input
Terminal
Terminal cover
Closed the terminal cover
±
0.5
±
0.5
Name Plate
As this product is adopted push-down type terminal block, this appearance is as follows.
1The terminal cover is retracted inside the unit.
2The screws for connecting the terminals are held in the up right position.
¡
Note when installing the EMI/EMC
Filter on a DIN rail.
When the EMI/EMC Filter is grounded through
the DIN rail, the proper noise attenuation may not
be achieved.
Be sure to connect the protection earth (PE) of
the EMI/EMC Filter body to the earth.
It can connect the ground to either one only.
92
12
2
15
53
80
41
30.52.5
8
7
8.2
(9)
±1.5
6-M4
Name Plate
Output
Terminal
Output
Terminal
Tolerance : ±1 [±0.04]
Weight : 270g max
Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04]
Case : PBT
Dimensions in mm, [ ]=inches
Terminal block screw tightening torque M4:1.6N-m (16.9kgf-cm) max
2-Protection Earth
Mounting Plate
Terminal cover
DIN rail
Input
Terminal
Input
Terminal
Terminal cover
Closed the terminal cover
[0.59]
[2.09]
[0.47]
[1.61]
[0.35]
[0.08][0.28]
[3.15]
[3.62] [0.32]
[0.1][1.2]
[0.31]
Standard Type
DIN rail installation Type
DIN rail
Name Plate
External view

NBM-10-331-D

Mfr. #:
Manufacturer:
Cosel
Description:
AC Power Line Filters Power Line Filters AC 1-250 / DC250 10A 37.5 uA/ 75 uA max
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union