GE
Data Sheet
JRW017-070 Series Power Modules DC-DC Converters
36-75Vdc Input; 1.2Vdc to 12Vdc Output
October 5, 2015 ©2012 General Electric Company. All rights reserved. Page 5
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
See Feature Descriptions for additional information.
Parameter Device Symbol Min Typ Max Unit
Remote On/Off Signal interface
(VI = VI,min to VI, max; Open collector or equivalent
Compatible, signal referenced to VI (-) terminal)
Ne
ative Lo
ic: device code suffix “1”
Logic Low=module On, Logic High=Module Off
Positive Lo
ic: No device code suffix re
uired
Logic Low=module Off, Logic High=Module On
Logic Low Specification
Remote On/Off Current-Logic Low All I
on/Off
— 0.15 1.0 mA
On/Off Voltage:
Logic Low
All
V
on/Off
0.0 — 1.2 V
Logic High (Typ=Open Collector)
All V
on/Off
— — 15 V
Logic High maximum allowable leakage current
All I
on/Off
— — 50
A
Turn-On Delay and Rise Times
(I
O
=I
O, max
)
T
delay
= Time until V
O
= 10% of V
O,set
from either P
T
delay
— 2 — msec
application of Vin with Remote On/Off set to On or M
—
2
—
msec
operation of Remote On/Off from Off to On with Vin Y
—
2
—
msec
already applied for at least one second. G
—
5
—
msec
F
—
2
—
msec
A
—
2.5
—
msec
B
—
2.5
—
msec
T
rise
= time for V
O
to rise from 10% of V
O,set
to 90% of
V
O,set
.
P
T
rise
— 1 — msec
M
—
1
—
msec
Y
—
1
—
msec
G
—
3
—
msec
F
—
1
—
msec
A
—
1
—
msec
B
—
1
—
msec
Output voltage adjustment range (TRIM)
Output Voltage Remote sense range V
sense
—
—
10
% V
O, nom
Output Voltage Set-point Adjustment range
80
—
110 % V
O, nom
Output Over voltage protection P
V
Oovsd
1.4
—
1.6
Vdc
M
1.8
—
2.2
Vdc
Y 2.3
—
2.6
Vdc
G 2.9
—
3.4
Vdc
F 3.8
—
4.6
Vdc
A 5.7
—
6.5
Vdc
B 14
—
16
Vdc
Over temperature Protection
All T
ref
127
°C
Input Undervoltage Lockout
V
in, OVLO
Turn-on Threshold
34.5
36
V
Turn-off Threshold
30 32.5
V