Input Specifications
Input current at no load 12 V; 3.3 & 5.0 VDC models: 85 mA typ. / 110 mA typ.
(nominal input voltage) 12 V; 12 & 15 VDC models: 160 mA typ.
12 V; 24 VDC models: 250 mA typ.
24 V; 3.3 & 5.0 VDC models: 50 mA typ. / 70 mA typ.
24 V; 12 & 15 VDC output models: 85 mA typ.
24 V; 24 VDC models: 110 mA typ.
48 V; 3.3 & 5.0 VDC models: 35 mA typ. / 45 mA typ.
48 V; 12 & 15 VDC models: 50 mA typ.
48 V; 24 VDC models: 60 mA typ.
Surge voltage (100 msec. max.) 12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Reflected input ripple current 12 Vin models: 50 mA typ.
24 Vin models: 40 mA typ.
48 Vin models: 30 mA typ.
Conducted noise (input) EN 55022 class A, FCC part 15 level A
with external input capacitor (1210 MLCC):
12 Vin models: 22 µF /25 V
24 Vin models: 3.3 µF /50 V
48 Vin models: 2.2 µF /100 V
Start-up voltage / under voltage shut down 12 Vin models: 9.0 VDC max./ 8.3 VDC (or lower)
24 Vin models: 18 VDC max./ 16.5 VDC (or lower)
48 Vin models: 36 VDC max./ 33 VDC (or lower)
Recommended input fuse (slow blow) 12 Vin models: 10 A
24 Vin models: 5 A
48 Vin models: 2.5 A
Conducted noise (input) EN 55022 class A with external capacitor
EMC immunity – ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
– Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
– Fast transient / surge (with external input capacitor) EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV perf. criteria A
Nippon chemi-con KXG 330 µF, 100 V
– Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy ±1.0 %
Output voltage adjustment range 24 VDC models: +20 / –10 %
other models: ±10 % with external resistor (see page 3)
Regulation – Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 0 – 100 % 0.5 % max.
Minimum load not required
Temperature coefficient ±0.02 %/K
Ripple and noise (20 MHz Bandwidth) 3.3 & 5.0 VDC models: 100 mVpk-pk. typ.
(measured with 1 µF MLCC and a 10 µF tantalum capacitor) 12, 15 & 24 VDC models: 150 mVpk-pk typ.
Transient response (alignment to 1% at load step change 75% to 100% ) 250 µs typ.
Output current limitation at 150% of Iout max.
Short circuit protection 24 VDC models: 0.3 Hz. typ.
other models: hiccup mode 1.5 Hz, automatic recovery
Capacitive load 3.3 VDC models: 25’800 µF max.
5.0 VDC models: 17’000 µF max.
12.0 VDC models: 2’900 µF max.
15.0 VDC models: 1’900 µF max.
24.0 VDC models: 750 µF max.
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.