AOZ8235
Rev. 2.0 November 2014 www.aosmd.com Page 2 of 6
Ordering Information
AOS Green Products use reduced levels of Halogens, and are also RoHS compliant.
Please visit www.aosmd.com/media/AOSGreenPolicy.pdf for additional information.
Absolute Maximum Ratings
Exceeding the Absolute Maximum ratings may damage the device.
Notes:
1. IEC 61000-4-2 discharge with C
Discharge
= 150 pF, R
Discharge
= 330 Ω.
2. Human Body Discharge per MIL-STD-883, Method 3015 C
Discharge
= 100 pF, R
Discharge
= 1.5 kΩ.
Maximum Operating Ratings
Electrical Characteristics
T
A
= 25°C unless otherwise specified.
Notes:
3. The working peak reverse voltage, V
RWM
, should be equal to or greater than the DC or continuous peak operating voltage level.
4. V
BR
is measured at the pulse test current I
T
.
Part Number Ambient Temperature Range Package Environmental
AOZ8235DI-05 -40 °C to +85 °C DFN 1.45 x 1.0 Green Product
RoHS Compliant
Parameter Rating
VP – VN 5 V
Peak Pulse Current (I
PP
), t
P
= 8/20 µs 4 A
Storage Temperature (T
S
) -65 °C to +150 °C
ESD Rating per IEC61000-4-2, Contact
(1)
±18 kV
ESD Rating per IEC61000-4-2, Air
(1)
±18 kV
ESD Rating per Human Body Model
(2)
±30 kV
Parameter Rating
Junction Temperature (T
J
) -40 °C to +125 °C
Symbol Parameter Conditions Min. Typ. Max. Units
V
RWM
Reverse Working Voltage Between pin 5 and 2
(3)
5.0 V
V
BR
Reverse Breakdown Voltage I
T
= 1 mA, between pins 5 and 2
(4)
6.0 V
I
R
Reverse Leakage Current V
RWM
= 5 V, any I/O pin to Ground 0.1 µA
V
F
Diode Forward Voltage I
F
= 10 mA, any I/O pin to Ground 0.7 V
V
CL
Channel Clamp Voltage
Positive Transients
Negative Transient
I
PP
= 15 A, tp = 100 ns, any I/O pin to Ground
12.0
-10.0
V
V
Channel Clamp Voltage
Positive Transients
Negative Transient
I
PP
= 25 A, tp = 100 ns, any I/O pin to Ground
15.0
-18.0
V
V
C
j
Junction Capacitance V
R
= 0 V, f = 1 MHz, any I/O pin to Ground 13.5 16.0 pF