Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight
@ 40°C (25°C) @ 250 VAC/50 Hz L Cx Cy R connections
(@ 120 VAC/60 Hz)
[A] [mA] [mH] [μF] [nF] [kΩ]
[g]
FN 2020-1-.. 1 (1.15) 0.66 (0.38) 12 0.15 4.7 1000 -06 -07 80
FN 2020-3-.. 3 (3.45) 0.66 (0.38) 2.5 0.15 4.7 1000 -06 -07 80
FN 2020-6-.. 6 (6.9) 0.66 (0.38) 1 0.15 4.7 1000 -06 -07 80
FN 2020-10-.. 10 (11.5) 0.66 (0.38) 0.8 0.15 4.7 1000 -06 -07 85
FN 2020-12-.. 12 (13.8) 0.66 (0.38) 0.7 0.15 4.7 1000 -06 -07 85
FN 2020-16-.. 16 (18.4) 0.66 (0.38) 0.65 0.15 4.7 1000 -06 -07 140
FN 2020-20-.. 20 (23) 0.66 (0.38) 0.6 0.15 4.7 1000 -06 -08 210
FN 2020-30-08 30 (34.5) 0.79 (0.45) 0.67 0.47 10 470 -08 470
FN 2020-60-24 60 (69) 0.79 (0.45) 1 1.5 10 220 -24 1100
FN 2020A-1-.. 1 (1.15) 0.07 (0.04) 12 0.15 0.47 1000 -06 -07 80
FN 2020A-3-.. 3 (3.45) 0.07 (0.04) 2.5 0.15 0.47 1000 -06 -07 80
FN 2020A-6-.. 6 (6.9) 0.07 (0.04) 1 0.15 0.47 1000 -06 -07 80
FN 2020A-10-.. 10 (11.5) 0.07 (0.04) 0.8 0.15 0.47 1000 -06 -07 85
FN 2020A-12-.. 12 (13.8) 0.07 (0.04) 0.7 0.15 0.47 1000 -06 -07 85
FN 2020A-16-.. 16 (18.4) 0.07 (0.04) 0.65 0.15 0.47 1000 -06 -07 140
FN 2020A-20-.. 20 (23) 0.07 (0.04) 0.6 0.15 0.47 1000 -06 -08 210
FN 2020A-30-08 30 (34.5) 0.07 (0.04) 0.67 0.47 0.47 470 -08 470
FN 2020A-60-24 60 (69) 0.07 (0.04) 1 1.5 0.47 220 -24 1100
FN 2020B-1-.. 1 (1.15) 0.00 12 0.15 1000 -06 -07 80
FN 2020B-3-.. 3 (3.45) 0.00 2.5 0.15 1000 -06 -07 80
FN 2020B-6-.. 6 (6.9) 0.00 1 0.15 1000 -06 -07 80
FN 2020B-10-.. 10 (11.5) 0.00 0.8 0.15 1000 -06 -07 85
FN 2020B-12-.. 12 (13.8) 0.00 0.7 0.15 1000 -06 -07 85
FN 2020B-16-.. 16 (18.4) 0.00 0.65 0.15 1000 -06 -07 140
FN 2020B-20-.. 20 (23) 0.00 0.6 0.15 1000 -06 -08 210
FN 2020B-30-08 30 (34.5) 0.00 0.67 0.47 470 -08 470
FN 2020B-60-24 60 (69) 0.00 1 1.5 220 -24 1100
*
* To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2020-30-08, FN 2020B-10-06).
** Maximum leakage under usual AC operating conditions (acc. IEC 60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
Leakage current for DC application is 0 mA;