30W Reliable Railway DC-DC Converter
RSD-30 series
Over Voltage Protection
LED Indicator
The converter shuts off to protect itself when the output voltage drawn exceeds 115~140% of its output rating. It must be repowered on to recover.
Equipped with a built-in LED indicator, the converter provides an easy way for users to check its condition through the LED indicator.
Green : normal operation; No signal: no power or failure.
2.Increase the output voltage (current does not change). Because RSD-30 series have no reverse blocking diode in the unit, you should add an external blocking diode
to prevent the damage of every unit while starting up. The voltage rating of the external diode should be larger than V1+V2 (as shown as below).
-
I/P
+
I/P
PS2
2
V
I/P
-
E
IN
PS1
I/P
1
+
V
-V
D
2
V1+V2
L
R
1
D
+V
Overload Protection
If the output draw up to 105~135% of its output power rating, the converter will go into overload protection which is constant current mode. After the faulty condition
is removed, it will recover automatically. Please refer to the diagram below for the detail operation characteristic. Please note that it's not suitable to operate within
the overload region continuously, or it may cause to over temperature and reduce the life of the power supply unit or even damage it.
0 50 100 150
50
100
Vo(%)
Io(%)
Derating Curve
AMBIENT TEMPERATURE ( )
LOAD (%)
100
100
20
40
60
80
-40 20 30 40 50 55 60 70
(HORIZONTAL)
Overload
region
a.Single unit operation
de-rating output current when ambient temperature is between 55~70 , please refer to the de-rating curve as below.
If the unit has no iron plate mounted on its bottom, the maximum ambient temperature for the unit will be 55 as operating under full load condition. It requires
File Name:RSD-30-SPEC 2018-01-12
30W Reliable Railway DC-DC Converter
RSD-30 series
AMBIENT TEMPERATURE ( )
LOAD (%)
100
100
20
40
60
80
-40 20 30 40 50 60 70
(HORIZONTAL)
b.Operate with additional iron plate
the bottom. The size of the suggested iron plate is shown as below. In order for optimal thermal performance, the iron plate must have an even & smooth surface
and RSD-30 series must be firmly mounted at the center of the iron plate.
If it is necessary to fulfil the requirements of EN50155 TX level that operate the unit fully-loaded at 70 , RSD-30 series must be installed onto an iron plate on
Suitable installation methods are shown as below. Since RSD-30 is a semi-potted model, its thermal performances for the following installation methods are similar
and share the same derating curve.
The load vs ambient temperature curve is shown as below.
Unit:mm
M3*4
Suitable installation methods are shown as below. Since RSD-30 is a semi-potted model, its thermal performances for the following installation methods are similar
and share the same derating curve.
iron plate
2
360
360
File Name:RSD-30-SPEC 2018-01-12
30W Reliable Railway DC-DC Converter
RSD-30 series
Immunity to Environmental Conditions
Test method
Cooling Test
Dry Heat Test
Damp Heat Test, Cyclic
Vibration Test
Increased Vibration Test
Shock Test
Low Temperature Storage Test
Standard
EN 50155 section 12.2.3 (Column 2, Class TX)
EN 60068-2-1
Temperature: -40
Dwell Time: 2 hrs/cycle
Temperature: 25 ~55℃℃
Humidity: 90%~100% RH
Duration: 48 hrs
Temperature: 19
Humidity: 65%
Duration: 10 mins
Temperature: 19
Humidity: 65%
Duration: 5 hrs
Temperature: 21 3±℃
Humidity: 65 5%±
Duration: 30ms*18
Temperature: -40
Dwell Time: 16 hrs
Temperature: 70 / 85℃℃
Duration: 6 hrs / 10min
EN 50155 section 12.2.5
EN 60068-2-30
EN 50155 section 12.2.11
EN 61373
EN 50155 section 12.2.11
EN 61373
EN 50155 section 12.2.11
EN 61373
EN 50155 section 12.2.3 (Column 2, Class TX)
EN 60068-2-1
EN 50155 section 12.2.4 (Column 2, Class TX)
EN 50155 section 12.2.4 (Column 3, Class TX & Column 4, Class TX)
EN 60068-2-2
Test conditions Status
No damage
PASS
PASS
PASS
PASS
PASS
PASS
Salt Mist Test
Temperature: 35 2℃±
Duration: 96 hrs
EN 50155 section 12.2.10 (Class ST4)
PASS
EN45545-2 Fire Test Conditions
Items
Test Items
R24
R25
R26
Oxygen index test
Glow-wire test
Vertical flame test
Standard
EN 45545-2:2013+A1:2015
EN ISO 4589-2:1996
Hazard Level
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
PASS
HL1 HL2 HL3
EN 45545-2:2013+A1:2015
EN 60695-2-11:2000
EN 45545-2:2013+A1:2015
EN 60695-11:2003
File Name:RSD-30-SPEC 2018-01-12

RSD-30G-24

Mfr. #:
Manufacturer:
Description:
DC/DC CONVERTER 24V 30W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union