SFH6742-X006

www.vishay.com For technical questions, contact: optocoupleranswers@vishay.com
Document Number: 82584
4 Rev. 2.1, 29-Apr-11
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
SFH6741, SFH6742, SFH6750, SFH6752
Vishay Semiconductors
High Speed Optocoupler, Single and Dual,
10 MBd
Fig. 1 - Single Channel Test Circuit for t
PLH
, t
PHL
, t
r
and t
f
Fig. 2 - Dual Channel Test Circuit for t
PLH
, t
PHL
, t
r
and t
f
Fig. 3 - Single Channel Test Circuit for t
EHL
, and t
ELH
1
2
3
4
8
7
6
5
18964-2
The probe and Jig capacitances are included in C
Input I
F
Output V
O
I
F
0 mA
V
OL
1.5 V
t
PHL
t
PLH
V
OH
C = 15 pF
GND
0.1 µF
bypass
V
CC
V
OUT
V
CC
I
F
R
R
L
Inpu tI
F
monitoring
node
Output V
O
monitoring
node
L
Single channel
Pulse gen.
Z = 50 Ω
t= t = 5 ns
o
f
r
M
L
= 7.5 mA
I
F
= 3.75 mA
V
E
1
2
3
4
8
7
6
5
GND
V
CC
Pulse Gen.
Z= 50 Ω
t= t =5n s
o
f
r
Input
Monitor ing
Node
Dual Channel
Output V
Monitor ing
Node
O
I
F
R
M
R
L
C
L
=1 5p F
0.1 µF
Bypass
18963-2
V
CC
1
2
3
4
8
7
6
5
18975-2
The probe and Jig capacitances are included in C
Inpu tV
E
Output V
O
t
EHL
t
ELH
C = 15 pF
GND
0.1 µF
bypass
V
CC
V
OUT
V
CC
I
F
R
L
Output V
O
monitoring
node
L
Single channel
Pulse gen.
Z = 50 Ω
t= t = 5 ns
o
f
r
L
7.5 mA
Input V
monitoring node
E
3 V
1.5 V
1.5 V
V
E
Document Number: 82584 For technical questions, contact: optocoupleranswers@vishay.com
www.vishay.com
Rev. 2.1, 29-Apr-11 5
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
SFH6741, SFH6742, SFH6750, SFH6752
High Speed Optocoupler, Single and Dual,
10 MBd
Vishay Semiconductors
Notes
(1)
For SFH6750
(2)
For SFH6741
(3)
For SFH6742 and SFH6752
Fig. 4 - Single Channel Test Circuit for Common Mode Transient Immunity
Fig. 5 - Dual Channel Test Circuit for Common Mode Transient Immunity
COMMON MODE TRANSIENT IMMUNITY
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Common mode transient immunity
(high)
|V
CM
| = 10 V, V
CC
= 5 V, I
F
= 0 mA,
V
O(min.)
= 2 V, R
L
= 350 , T
amb
= 25 °C
(1)
|CM
H
|100 V/μs
|V
CM
| = 50 V, V
CC
= 5 V, I
F
= 0 mA,
V
O(min.)
= 2 V, R
L
= 350 , T
amb
= 25 °C
(2)
|CM
H
| 5000 10 000 V/μs
|V
CM
| = 1 kV, V
CC
= 5 V, I
F
= 0 mA,
V
O(min.)
= 2 V, R
L
= 350 , T
amb
= 25 °C
(3)
|CM
H
| 10 000 15 000 V/μs
|V
CM
| = 10 V, V
CC
= 5 V, I
F
= 7.5 mA,
V
O(max.)
= 0.8 V, R
L
= 350 , T
amb
= 25 °C
(1)
|CM
L
|100 V/μs
|V
CM
| = 50 V, V
CC
= 5 V, I
F
= 7.5 mA,
V
O(max.)
= 0.8 V, R
L
= 350 , T
amb
= 25 °C
(2)
|CM
L
| 5000 10 000 V/μs
|V
CM
| = 1 kV, V
CC
= 5 V, I
F
= 7.5 mA,
V
O(max.)
= 0.8 V, R
L
= 350 , T
amb
= 25 °C
(3)
|CM
L
| 10 000 15 000 V/μs
V
CM
(PEAK)
Switch AT A: I
F
Switch AT A:
V
O
(min.
V
O
(max.)
0 V
5 V
V
CM
V
O
V
O
0.5 V
CM
H
CM
L
1
2
3
4
8
7
6
5
18976-2
GND
0.1 µF
bypass
V
CC
V
OUT
V
CC
R
L
Output V
O
monitoring
node
+
-
V
CM
Single channel
B
A
V
FF
I
F
Pulse generator
Z = 50 Ω
O
V
E
)
= 0 mA
I
F
= 7.5 mA
1
2
3
4
8
7
6
5
18977
GND
0. 1 µF
Bypass
V
CC
R
L
+5V
Output V
O
Monitoring
Node
+
-
V
CM
B
A
V
FF
I
F
Pulse Generator
Z = 50 Ω
O
Dual Channel
www.vishay.com For technical questions, contact: optocoupleranswers@vishay.com
Document Number: 82584
6 Rev. 2.1, 29-Apr-11
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
SFH6741, SFH6742, SFH6750, SFH6752
Vishay Semiconductors
High Speed Optocoupler, Single and Dual,
10 MBd
Note
As per IEC 60747-5-2, §7.4.3.8.1, this optocoupler is suitable for “safe electrical insulation” only within the safety ratings. Compliance with
the safety ratings shall be ensured by means of prodective circuits.
TYPICAL CHARACTERISTICS (T
amb
= 25 °C, unless otherwise specified)
Fig. 6 - Forward Voltage vs. Ambient Temperature
Fig. 7 - Forward Voltage vs. Forward Current
Fig. 8 - Reverse Current vs. Ambient Temperature
Fig. 9 - Low Level Supply Current vs. Ambient Temperature
SAFETY AND INSULATION RATINGS
PARAMETER TEST CONDITION SYMBOL MIN. TYP. MAX. UNIT
Climatic classification according to IEC 69 part 1 55/110/21
Comparative tracking index CTI 175 399
Peak transient overvoltage V
IOTM
8000 V
Peak insulation voltage V
IORM
630 V
Safety rating - power output P
SO
500 mW
Safety rating - input current I
SI
300 mA
Safety rating - temperature T
SI
175 °C
Creepage distance Standard DIP-8 7 mm
Clearance distance Standard DIP-8 7 mm
Creepage distance 400 mil DIP-8 8 mm
Clearance distance 400 mil DIP-8 8 mm
Insulation thickness, reinforced rated per IEC60950.2.10.5.1 0.2 mm
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
- 40 - 20 0 20 40 60 80 100
T
amb
- Ambient Temperature (°C)
17610
I
F
= 50 mA
I
F
= 10 mA
I
F
= 20 mA
I
F
= 1 mA
V
F
- Forward Voltage (V)
1.10
1.15
1.20
1.25
1.30
1.35
1.40
1.45
1.50
1.55
1.60
0101520253035404550
I
F
- Forward Current (mA)
17611
V
F
- Forward Voltage (V)
5
0
1
2
3
4
5
6
7
- 40 - 20 0 20 40 60 80 100
I
R
- Reverse Current (nA)
T
amb
- Ambient Temperature (°C)
17613-1
V
R
= 5 V
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
- 40 - 20 0 20 40 60 80 100
I
CCI
- Low Level Supply Current (mA)
T
amb
- Ambient Temperature (°C)
17614
V
CC
= 5 V
I
F
= 10 mA
I
F
= 10 mA
V
CC
= 7 V

SFH6742-X006

Mfr. #:
Manufacturer:
Description:
High Speed Optocouplers 10Mbd High-Speed w/Optical Photodiode
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet