TAT-125-1-6-STK

Page 4 SPECIFICATION RW-3032 ISSUE 1
If this document is printed it becomes uncontrolled. Check for the latest revision.
TABLE 1
Tubing Dimensions
Dimensions
-
inches (mm)
Size
Minimum
As Supplied I.D.
Maximum
Recovered I.D.
Nominal
Recovered Wall
With Adhesive
Nominal Recovered
Adhesive Thickness
1/8
.125 (3.17) .062 (1.57)
.027 (0.68) .009 (0.23)
3/16
.187 (4.74)
.093 (2.36) .028 (0.71) .010 (0.25)
1/4 .250 (6.35) .125 (3.17) .029 (0.74) .005 (0.13)
3/8 .375 (9.50) .187 (4.74) .029 (0.74) .005 (0.13)
1/2 .500 (12.7) .250 (6.35) .030 (0.76) .006 (0.15)
3/4 .750 (19.05) .375 (9.50) .035 (0.89) .006 (0.15)
1 1.00 (25.40) .500 (12.7) .042 (1.06) .008 (0.20)
1-1/2 1.50 (38.10) .750 (19.05) .047 (1.20) .011 (0.28)
2 2.00 (50.80) 1.000 (25.40) .065 (1.65) .022 (0.56)
3 3.00 (76.20) 1.500 (38.10) .065 (1.65) .022 (0.56)
4 4.00 (101.60) 2.000 (50.80) .070 (1.78) .020 (0.51)
TABLE 2
Mandrel Dimensions for Bend Testing
Tubing Size Mandrel Diameter
in.
mm.
1/8” to ¼” inclusive 5/16 7.9
3/8” to ¾” inclusive 1/2 12.7
1” to 4 “ 9/16 14.3
SPECIFICATION RW-3032 ISSUE 1 Page 5
If this document is printed it becomes uncontrolled. Check for the latest revision.
TABLE 3
Requirements
PROPERTY UNIT REQUIREMENT TEST METHOD
PHYSICAL
Dimensions
Inches (mm)
In accordance with
Table 1
Section 4.3.1
ASTM D 2671
Longitudinal Change Percent +1, -5 ASTM D 2671
Tensile Strength psi (MPa) 1500 minimum (10.3) Section 4.3.2
ASTM D 2671
Ultimate Elongation Percent 200 minimum
Secant Modulus (Expanded) psi (MPa)
2.5 x 10
4
maximum
(172)
ASTM D 882, 2%
strain
Cold Impact
at -55 ± 2°C (-67 ± 4°F)
--- No more than 5 of 10
crack
ASTM D 746
Proc. A
Heat Shock
4 hours at 250 ± 3°C (482 ± 5°F)
--- No dripping, flowing
or cracking of outer
wall
Table 2 mandrels
ASTM D 2671
Heat Resistance
168 hours at 175 ± 2°C (347 ± 4°F)
Followed by test for mandrel bend
--- --- ASTM D 2671
Table 2 mandrels
360 ° bend in 10 ± 2
seconds
Color Stability
48 hours at 175 ± 2°C (347 ± 4°F)
--- MIL-STD-104 ASTM D 2671
ELECTRICAL
Dielectric Strength
Volts/mil
(volts/mm)
500 minimum
(19,680) on dual wall
specimen
NOTE 1
ASTM D 2671
Volume Resistivity ohm-cm
10
14
minimum on
dual wall specimen
ASTM D 2671
CHEMICAL
Copper Mirror Corrosion 16 hours at 121 ±
2°C (250 ± 4°F)
-
--
No removal of copper
ASTM D 2671
Procedure A
Copper Contact Corrosion
16 hours at 121 ± 2°C (250± 4°F)
--- No pitting or
blackening of copper
ASTM D 2671
Procedure B
Page 6 SPECIFICATION RW-3032 ISSUE 1
If this document is printed it becomes uncontrolled. Check for the latest revision.
TABLE 3
Requirements
(continued)
PROPERTY UNIT TYPE 1 TYPE 2 TEST METHOD
CHEMICAL (continued)
Flammability (jacket only)
---
Self-
extinguishing
within
1 minute, 25%
maximum flag
burn
---
ASTM D 2671
Procedure B
Water Absorption
24 hours at 23°C (73°F)
Percent 0.5 maximum 0.2 maximum ASTM D 2671
Fluid Resistance
24 hours at 23°C (73°F) in:
JP-8 Turbine Fuel (MIL-T-83133)
Skydrol 500B
Hydraulic Fluid (MIL-PRF-5606)
Avaiation Gasoline (100/130)
5% NaCl Water
Followed by tests for:
--- --- --- ASTM D 2671
Dielectric Strength Volts/mil
(volts/mm)
400 minimum
(15,760)
400 minimum
(15, 760)
Tensile Strength psi (MPa) 1000 minimum
(6.9)
1000 minimum
(6.9)
Fungus Resistance
Followed by tests for:
Tensile Strength
Ultimate Elongation
Dielectric Strength
psi (Mpa)
percent
Volts per mil
(volts per mm)
1500 minimum
(10.3)
200 minimum
500 minimum
(19,680)
1500 minimum
(10.3)
200 minimum
500 minimum
(19,680)
ISO 846
Method B
Section 4.3.2
ASTM D 2671
ASTM D 2671
*Trademark of the Monsanto Company
NOTE 1: Recover the specimens on the metal mandrels for 10 minutes, minimum, at 150 ± 3°C (302 ± 5°F) or until the
tubing is completely shrunk on the mandrels.

TAT-125-1-6-STK

Mfr. #:
Manufacturer:
TE Connectivity
Description:
Heat Shrink Tubing and Sleeves TAT-125-1-6-STK PRICE PER FOOT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union