M74HC4851 Absolute maximum ratings and operating conditions
Doc ID 8640 Rev 7 7/16
I
IN
Control input
current
6.0 V
IN
= V
CC
or GND ± 0.1 ± 0.1 ± 1 μA
I
CC
Quiescent
supply current
6.0
V
IN
= V
CC
or GND
V
IN(analog)
= GND
22040μA
Table 6. DC specifications (continued)
Symbol Parameter
Test condition Value
Unit
V
CC
(V)
T
A
= 25 °C Up to 85 °C Up to 125 °C
Min. Typ. Max. Min. Max. Min. Max.
Table 7. AC electrical characteristics (C
L
= 50 pF, input t
r
= t
f
= 6 ns)
Symbol Parameter
Test condition Value
Unit
V
CC
(V)
Test circuit 1
T
A
= 25 °C Up to 85 °C Up to 125 °C
Min. Typ. Max. Min. Max. Min. Max.
t
PHL,
t
PL
H
Propagation
delay time,
analog input to
analog output
2.0 19.5 25 29 32
ns
3.0 12 15.5 17.5 19.5
3.3 11 14.5 16.5 18.5
4.5 8.6 11.5 12.5 13.5
6.0 8 10 11 12
t
PHL,
t
PLH
Propagation
delay time
channel-select
to analog
output
2.0 23 30 35 40
ns
3.0 13.5 17.5 20 23
3.3 12.5 16.5 19 22
4.5 10 13 15 17
6.0 9.5 12.5 14.5 16.5
t
PHZ
,
t
PZH
t
PLZ,
t
PZL
Enable disable
time, enable or
channel-select
to analog
output
2.0 95 105 115
ns
3.0 90 100 110
3.3 85 95 105
4.5 80 90 100
6.0 78 80 80
C
IN
Input
capacitance
(digital pins)
3.5 10 10 10 pF
C
IN
Input
capacitance
(switches off,
any single
analog pins)
6.7 15 15 15 pF
Absolute maximum ratings and operating conditions M74HC4851
8/16 Doc ID 8640 Rev 7
C
IN
Input
capacitance
(switches off,
any common
analog pins)
22 40 40 40 pF
C
PD
Power
dissipation
capacitance
(1)
3.3 24
pF
5.0 28
1. C
PD
is defined as the value of the IC’s internal equivalent capacitance which is calculated from the operating current
consumption without load (refer to Figure 5). The average operating current can be obtained by the following equation:
I
CC
(opr) = C
PD
x V
CC
x f
IN
+ I
CC
/8.
Table 7. AC electrical characteristics (C
L
= 50 pF, input t
r
= t
f
= 6 ns) (continued)
Symbol Parameter
Test condition Value
Unit
V
CC
(V)
Test circuit 1
T
A
= 25 °C Up to 85 °C Up to 125 °C
Min. Typ. Max. Min. Max. Min. Max.
Table 8. Injection current coupling specification (T
A
= -55°C to +125°C)
Symbol Parameter
Test condition Value
Unit
V
CC
(V)
Test circuit 2 Typ.
(1)
Max.
V
ΔOUT
Shift of output
voltage of
enabled
analog
channel
3.3
I
IN
1 mA, R
S
3.9 kΩ
0.050 1.0
mV
5.0 0.100 1.0
3.3
I
IN
10 mA, R
S
3.9 kΩ
0.345 5.0
5.0 0.067 5.0
3.3
I
IN
1 mA, R
S
20 kΩ
0.050 2.0
5.0 0.110 2.0
3.3
I
IN
10 mA, R
S
20 kΩ
0.050 20
5.0 0.024 20
1. Typical values are measured at T
A
= 25 °C. They are calculated as the difference from V
OUT
without injection current and
V
OUT
with injection current. I
IN
= total current injected into any other disabled channels, one at time.
M74HC4851 Absolute maximum ratings and operating conditions
Doc ID 8640 Rev 7 9/16
Figure 5. Test circuit 1
Note: C
L
= 50 pF or equivalent (includes jig and probe capacitance).
R
L
= R1 = 10 k
Ω
or equivalent.
R
T
= Z
OUT
of pulse generator (typically 50
Ω
).
Figure 6. Test circuit 2
Table 9. Test circuit 1 - switch configuration table
Test Switch
t
PLH
, t
PHL
Open
t
PZL
, t
PLZ
V
CC
t
PZH
, t
PHZ
GND

M74HC4851B1R

Mfr. #:
Manufacturer:
STMicroelectronics
Description:
Encoders, Decoders, Multiplexers & Demultiplexers 8-Ch Ana Multi/Demul
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union