EVAL-ADGM1004EBZ

UG-1078 EVAL-ADGM1004EBZ User Guide
Rev. 0 | Page 4 of 11
Table 3. (RF1) to (RF4) Links and IN1 to IN4 SMB Connector Settings
Link Name Controlled RF Switch Logic Input Link Position RF Switch Status
(RF1) RF1 to RFC Header Off (default setting) Off
On On
SMB Off Controlled via the IN1 SMB (low is off, high is on)
(RF2) RF2 to RFC Header Off (default setting) Off
On On
SMB Off Controlled via the IN2 SMB (low is off, high is on)
(RF3) RF3 to RFC Header Off (default setting) Off
On On
SMB
Off
(RF4) RF4 to RFC Header Off (default setting) Off
On On
SMB Off Controlled via the IN4 SMB (low is off, high is on)
EVAL-ADGM1004EBZ User Guide UG-1078
Rev. 0 | Page 5 of 11
MEASURING SWITCH PERFORMANCE
Figure 1 shows the EVA L -ADGM1004EBZ evaluation board of
the ADGM1004. Apply a V
DD
supply to the evaluation board to
measure the performance of the switch. The links are set
according to the switch under test (see Table 3). After selecting
the desired channel and its state, the switch performance data
can be collected using a network analyzer. Terminate the RFx
edge connectors of unused switch channels into 50loads to
achieve the full performance of the channel under test.
The EVA L-ADGM1004EBZ, shown in Figure 1, comes with a
calibration transmission line, CALIBRATION THRU, on the
PCB. This calibration line removes the insertion loss and phase
offset of the PCB transmission lines connecting to the switch from
the measurement. Figure 2 shows the calibration transmission line
and Figure 3 shows its insertion loss and return loss up to 16 GHz.
The calibration line is exactly the same length as the distance
from any one RFx connector to the RFx pin of the device, plus
the distance from the RFC connector to the RFC pin of the device.
15240-102
Figure 2. EVAL-ADGM1004EBZ Calibration Transmission Line Used for PCB
Insertion Loss and Phase Offset Correction
0
–3.0
0
–50
–40
–30
–20
–10
–2.5
–2.0
–1.5
–1.0
–0.5
0 2.5 5.0 7.5 10.0 12.5 15.0
INSERTION LOSS (dB)
RETURN LOSS (dB)
FREQUENCY (GHz)
S(2,1)
S(1,1)
15240-002
Figure 3. Calibration Transmission Line Insertion Loss and Return Loss
Figure 4 illustrates the calibration line length. All RF traces
connecting to the ADGM1004 are of equal length.
A
B
15240-003
Figure 4. Calibration Transmission Line Length Equal to the A + B Length
To deembed the PCB transmission line insertion loss from the
entire switch insertion loss board measurement (the RF1 to
RFC path), divide the S(2,1) of measured data by the |S(2,1)| of
the CALIBRATION THRU line. Perform this deembedding by
using the network analyzer at the time of the measurement or after
the measurement using individual measurement data files. Refer
to the Network Analyzer Calibration Procedure section for
more information.
Use the network analyzer port extension function to deembed
the phase offset introduced by the PCB transmission lines. The
port extension method uses time delay offset values to correct
for phase. Enter the time delays into the port extension menu
on the network analyzer corresponding to the phase offset
introduced from an RF edge connector to the switch pin. Figure 4
shows an example of these phase offsets on a typical switch
measurement, labeled as A and B. Both A and B are identical in
length and can be calculated by measuring the time delay of the
calibration line and dividing it by two.
UG-1078 EVAL-ADGM1004EBZ User Guide
Rev. 0 | Page 6 of 11
Figure 5 shows the ADGM1004 switch insertion loss (network
analyzer two-port S(2,1) measurement) measurement results that
are deembedded with respect to the PCB transmission line losses.
The blue trace is the RF2 to RFC switch channel, and the red
trace is the RF1 to RFC switch channel. The dashed traces are the
respective return loss traces. The performance of the RF2 switch
is identical to the RF3 switch, and the RF1 switch is identical to the
RF4 switch.
0
–3.0
0
–50
–40
–30
–20
–10
–45
–35
–25
–15
–5
–2.5
–2.0
–1.5
–1.0
–0.5
0 2 4 6 8 10 12 14 16
INSERTION LOSS (dB)
RETURN LOSS (dB)
FREQUENCY (GHz)
15240-004
RF2 TO RFC CHANNEL
RF1 TO RFC CHANNEL
RF2 TO RFC CHANNEL
RF1 TO RFC CHANNEL
Figure 5. PCB Deembedded ADGM1004 Insertion Loss and Return Loss
Performance
Figure 6 shows the ADGM1004 switch off isolation performance
measurement results for two channels. The blue trace is the RF2
to RFC switch channel, and the red trace is the RF1 to RFC switch
channel. As with insertion loss, the performance of the RF2
switch is identical to the RF3 switch and the RF1 switch is identical
to the RF4 switch.
0
–80
–70
–60
–50
–40
–30
–20
–10
0108642
OFF ISOLATION (dB)
FREQUENCY (GHz)
RF2 TO RFC CHANNEL
RF1 TO RFC CHANNEL
15240-005
Figure 6. ADGM1004 Off Isolation Performance