SMM02070C2209FBP00

SMM0207
www.vishay.com
Vishay Draloric
Revision: 04-Dec-15
7
Document Number: 20005
For technical questions, contact: melf@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
101100m10m
1m
100μ10μ
0.1
100
10
1
1000
Pulse Load
P
max.
in W
Single Pulse
Maximum pulse load, single pulse; applicable if P 0 and n 1000 and U U
max.
;
for permissible resistance change equivalent to 8000 h operation in power operation mode
Pulse Duration t
i
in s
in W
Pulse Duration t
i
in s
101100m10m
1m
100μ10μ
0.1
100
10
1
1000
Continuous Pulse Load
P
max.
Continuous Pulse
Maximum pulse load, continuous pulses; applicable if P P (
ϑ
amb
) and U U
max.
;
for permissible resistance change equivalent to 8000 h operation in power operation mode
Pulse Duration t
i
in s
101100m10m
1m
100μ10μ
Pulse Voltage
Maximum pulse voltage, single and continuous pulses; applicable if P P
max.
;
for permissible resistance change equivalent to 8000 h operation in power operation mode
Pulse Voltage
U
max.
in V
600
1600
0
200
400
800
1000
1200
1400
SMM0207
www.vishay.com
Vishay Draloric
Revision: 04-Dec-15
8
Document Number: 20005
For technical questions, contact: melf@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
TESTS AND REQUIREMENTS
All tests are carried out in accordance with the following
specifications:
EN 60115-1, generic specification
EN 60115-8 (successor of EN 140400), sectional
specification
EN 140401-803, detail specification
IEC 60068-2-xx, test methods
The parameters stated in the Test Procedures and
Requirements table are based on the required tests and
permitted limits of EN 140401-803. The table presents only
the most important tests, for the full test schedule refer to
the documents listed above. However, some additional
tests and a number of improvements against those
minimum requirements have been included.
The testing also covers most of the requirements specified
by EIA/ECA-703 and JIS-C-5201-1.
The tests are carried out under standard atmospheric
conditions in accordance with IEC 60068-1, 4.3, whereupon
the following values are applied:
Temperature: 15 °C to 35 °C
Relative humidity: 25 % to 75 %
Air pressure: 86 kPa to 106 kPa (860 mbar to 1060 mbar).
A climatic category LCT / UCT / 56 is applied, defined by the
lower category temperature (LCT), the upper category
temperature (UCT), and the duration of exposure in the
damp heat, steady state test (56 days).
The components are mounted for testing on printed circuit
boards in accordance with EN 60115-8, 2.4.2, unless
otherwise specified.
TEST PROCEDURES AND REQUIREMENTS
EN
60115-1
CLAUSE
IEC
60068-2
(1)
TEST
METHOD
TEST PROCEDURE
REQUIREMENTS
PERMISSIBLE CHANGE (R)
Stability for
product types:
STABILITY
CLASS 0.25
OR BETTER
STABILITY
CLASS 0.5
OR BETTER
STABILITY
CLASS 1
OR BETTER
STABILITY
CLASS 2
OR BETTER
SMM0207 < 1 1 to < 10 10 to < 1 M > 1 M
4.8 -
Temperature
coefficient
(1)
At (20 / -55 / 20) °C
and (20 / 125 / 20) °C
± 100 ppm/K, ± 50 ppm/K, ± 25 ppm/K; ±15 ppm/K
4.25.1 -
Endurance
at 70 °C:
precision
operation mode
U =
U
max.
;
1.5 h on; 0.5 h off;
70 °C; 1000 h
-
± (0.05 %
R+0.005)
-
70 °C; 8000 h
± (0.1 %
R+0.005)
Endurance
at 70 °C:
standard
operation mode
U =
U
max.
;
1.5 h on; 0.5 h off;
70 °C; 1000 h ± (0.15 % R+0.01 (0.5 % R)
70 °C; 8000 h ± (0.3 % R+0.01 (1 % R)
Endurance
at 70 °C:
power
operation mode
U =
U
max.
;
1.5 h on; 0.5 h off;
70 °C; 1000 h ± (0.25 % R+0.01 (0.5 % R)
70 °C; 8000 h ± (0.5 % R+0.01 (1 % R)
4.25.3 -
Endurance at
upper category
temperature
125 °C; 1000 h ± (0.15 % R+0.01 (0.5 % R)
155 °C; 1000 h ± (0.3 % R+0.01 (1 % R)
4.24 78 (Cab)
Damp heat,
steady state
(40± 2) °C;
56days;
(93 ± 3) %RH
± (0.25 % R+0.01 (1 % R)
P
70
x R
P
70
x R
P
70
x R
SMM0207
www.vishay.com
Vishay Draloric
Revision: 04-Dec-15
9
Document Number: 20005
For technical questions, contact: melf@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
4.37 67 (Cy)
Damp heat,
steady state,
accelerated
(85 ± 2) °C
(85 ± 5) % RH
U = 0.3 x
100 V and
U = 0.3 x U
max.
;
(the smaller
value is valid)
1000 h
± (0.5 % R+0.01 (2 % R)
- 1 (Ab) Cold -55 °C; 2000 h ± (0.1 % R+0.01)
4.19 14 (Na)
Rapid
change of
temperature
30min at LCT and
30min at UCT;
LCT = -55 °C;
UCT = 125 °C;
1000 cycles
± (0.25 % R+0.01)
LCT = -55 °C;
UCT = 155 °C;
1000 cycles
± (0.5 % R+0.01)
4.13 -
Short time
overload:
standard
operation
mode
U= 2.5 x
2 x U
max.
; 5 s
± (0.03 % R+0.01) ± (0.15 % R)
Short time
overload:
power
operation
mode
± (0.05 % R+0.01) ± (0.15 % R)
4.27 -
Single pulse
high voltage
overload:
standard
operation
mode
Severity no. 4:
U= 10 x
2 x U
max.
;
10 pulses
10 μs/700 μs
± (0.25 % R+0.01)
Single pulse
high voltage
overload:
power
operation
mode
± (0.5 % R+0.01)
4.39 -
Periodic
electric
overload:
standard
operation
mode
U =
2 x U
max.
;
0.1 s on; 2.5 s off;
1000 cycles
± (0.15 % R+0.01)
Periodic
electric
overload:
power
operation
mode
± (0.3 % R+0.01)
TEST PROCEDURES AND REQUIREMENTS
EN
60115-1
CLAUSE
IEC
60068-2
(1)
TEST
METHOD
TEST PROCEDURE
REQUIREMENTS
PERMISSIBLE CHANGE (R)
Stability for
product types:
STABILITY
CLASS 0.25
OR BETTER
STABILITY
CLASS 0.5
OR BETTER
STABILITY
CLASS 1
OR BETTER
STABILITY
CLASS 2
OR BETTER
SMM0207 < 1 1 to < 10 10 to < 1 M > 1 M
P
70
x R
P
70
x R
P
70
x R
15 x P
70
x R

SMM02070C2209FBP00

Mfr. #:
Manufacturer:
Vishay
Description:
MELF Resistors 1watt 22ohms 1% 50ppm
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: