CONSTANT CURRENT REGION
Note.4
SPECIFICATION
MODEL
DC VOLTAGE
OUTPUT
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
MAX. NO. of PSUs on 16A
CIRCUIT BREAKER
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
MAX. CASE TEMP.
STORAGE TEMP., HUMIDITY
VIBRATION
MTBF
DIMENSIONOTHERS
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
47 ~ 63Hz
PF 0.98/115VAC, PF 0.97/230VAC, PF 0.95/277VAC @ full load≧≧≧
5A / 115VAC 2.45A / 230VAC 2A / 277VAC
<0.75mA / 277VAC
2unit(circuit breaker of type B) / 3units(circuit breaker of type C) at 230VAC
95 ~ 108%
Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN55032 (CISPR32) Class B EN55015, EN61000-3-2 Class C (@ load 50%) ; EN61000-3-3; GB17743, GB17625.1 EAC TP TC 020
,
≧ ,
Compliance to ,EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV) EAC TP TC 020
20 ~ 95% RH non-condensing
Tcase= +90℃
-40 ~ +80 , 10 ~ 95% RH℃ non-condensing
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
345.5K hrs min. Telcordia SR-332(Bellcore) ; 95.3K hrs min. MIL-HDBK-217F (25 )
℃
262*125*43.8mm (L*W*H)
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
94%
94.5%
94.5%
95%
95%
95.5%
95%
95.5%
94.5%
95%
95%
95%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
10 ~ 20A 8 ~ 16A 6.6 ~ 13.3A 5.7 ~ 11.4A 5 ~ 10A 4.4 ~ 8.9A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
24V
HLG-480H-24 HLG-480H-30 HLG-480H-36 HLG-480H-42 HLG-480H-48 HLG-480H-54
30V 36V 42V 48V 54V
12 ~ 24V 15 ~ 30V 18 ~ 36V 21 ~ 42V 24 ~ 48V 27 ~ 54V
EMC IMMUNITY
EMC EMISSION
COLD START 35A(t =1800 s measured at 50% I ) at 230VAC; Per NEMA 410
width peak
TOTAL HARMONIC DISTORTION
480W Constant Voltage + Constant Current LED Driver
HLG-480H series
File Name:HLG-480H-SPEC 2018-08-03
THD< 20% (@ load 40% / 115VAC,230VAC,277VAC)≧
(Please refer to TOTAL HARMONIC DISTORTION (THD) section)""
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
UL8750(type”HL”), CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.14,GB19510.1;
IP65 or IP67 approved,,EAC TP TC 004 AS/NZS 60950.1(by CB)
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
16ms 115VAC/230VAC
500ms, 80ms 115VAC/230VAC
90 ~ 305VAC 127 ~ 431VDC
(Please refer to "STATIC CHARACTERISTIC" section)
Tcase= -40 ~ +90℃
(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
Shut down output voltage, re-power on to recovery
Shut down output voltage, re-power on to recovery
RATED CURRENT
RATED POWER
VOLTAGE ADJ. RANGE
RIPPLE & NOISE (max.)
Note.2
20A 16A 13.3A 11.4A 10A 8.9A
480W 480W 478.8W 478.8W 480W 480.6W
200mVp-p 200mVp-p 250mVp-p 250mVp-p 250mVp-p 350mVp-p
Adjustable for A-Type only (via built-in potentiometer)
Adjustable for A-Type only (via built-in potentiometer)
20.4 ~ 25.2V 25.5 ~ 31.5V 30.6 ~ 37.8V 35.7 ~ 44.1V 40.8 ~ 50.4V 45.9 ~ 56.7V
27 ~ 33V 33 ~ 40V 40 ~ 50V 46 ~ 55V 53 ~ 63V 60 ~ 70V
(Please refer to " " section)POWER FACTOR (PF) CHARACTERISTIC
ISOLATION RESISTANCE
WITHSTAND VOLTAGE
TEMP. COEFFICIENT
±℃ ℃0.02%/ (0 ~ 60 )
PACKING
2.8Kg;4pcs/12.2Kg/0.55CUFT
NOTE
1. parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.
All ℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. driver
The is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED can only be used behind a switch without permanently
driver
connected to the mains.
9. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75 or less. ℃
10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
11. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
μ
EFFICIENCY
(Typ.)
230VAC
277VAC