5.0 ENVIRONMENTAL PERFORMANCE SPECIFICATIONS
Item Test Condition Requirement
5.1 Damp Heat (cyclic) Temp 25°C-55 °C and 90-100% No change in the readability
IEC 68-2-30 Db humidity for 6 cycles of 24 hours of the laser marking
(Cycle: 25 °C-55 °C in 3 hours
9 hours at 55 °C
55 °C-25 °C in 3 hours
9 hours at 25 °C
Recovery at 25 °C and 25-75%
humidity for 2 hours)
5.2 Cold Storage 96 hours in -40 °C No change in the readability
IEC 68-2-1 Ab Recovery 2 hours at room temp of the laser marking
5.3 Dry Heat Storage 96 hours in +85 °C No change in the readability
IEC68-2-2Bb Recovery 2 hours at room temp of the laser marking
5.4 Thermal Shock -55 °C to +85 °C (change < 3 min) No change in the readability
IEC 68-2-14 Na 50 cycles, 1 cycle 0.5 + 0.5 hours, of the laser marking
recovery time 2 hours at room temp
5.5 Gradual change From -55 °C to +125 °C at steps of No change in the readability
of temperature 10 °C/hr, starting at 25 °C to of the laser marking
min/max temp
5.6 Reflow Test Reflow the connector as per Solders correctly to PWB.
Appendix 8.1. No change in the readability
of the laser marking
5.7 Solderability TestReflow the connector as per Solders correctly to PWB.
Appendix 8.2. No change in the readability
of the laser marking
5.8 Salt Spray 48hour spray, at temp. 35
o
+/-2
o
C No change in the readability
IEC512-5, test11f R/H 90-95% Salt NaCl mist 5% of the laser marking
After test wash parts and return to room
Temperature for 1-2 hours
5.9 Mixed Gas 96 hours. H
2
S 3ppm + SO
2
10ppm No change in the readability
IEC68-2-42 Kc At temp 40 °C +/- 2 °C, R/H 80% of the laser marking
After test return to ambient for 1-2 hours
ENGLISH
LANGUAGE
PRODUCT SPECIFICATION
ES-40000-3996 REV. A SHEET 4 95/MAR/10 EC U5-0926 DCBRD03.LWP
3
PS-91658-010
SHEETFILENAME
DOCUMENT NUMBER
INC. AND MUST NOT BE USED WITHOUT WRITTEN PERMISSION
DESCRIPTIONREV.
THIS DOCUMENT CONTAINS INFORMATION THAT IS PROPRIETARY TO
FOR TRACEABILITY PAD
A
PRODUCT SPECIFICATION
TITLE:
REVISE ON PC ONLY