μ
PG2163T5N
R09DS0019EJ0300 Rev.3.00 Page 7 of 8
May 19, 2011
RECOMMENDED SOLDERING CONDITIONS
This product should be soldered and mounted under the following recommended conditions. For soldering methods
and conditions other than those recommended below, contact your nearby sales office.
Soldering Method Soldering Conditions Condition Symbol
Infrared Reflow Peak temperature (package surface temperature) : 260°C or below
Time at peak temperature : 10 seconds or less
Time at temperature of 220°C or higher : 60 seconds or less
Preheating time at 120 to 180°C : 120±30 seconds
Maximum number of reflow processes : 3 times
Maximum chlorine content of rosin flux (% mass) : 0.2%(Wt.) or below
IR260
Partial Heating Peak temperature (terminal temperature) : 350°C or below
Soldering time (per side of device) : 3 seconds or less
Maximum chlorine content of rosin flux (% mass) : 0.2%(Wt.) or below
HS350
Caution Do not use different soldering methods together (except for partial heating).
<R>