DLW5BTM251TQ2L

Spec. No. JEFL243C-0025G-01 P 4/10
MURATA MFG CO.,LTD.
Reference Only
9. Enviromental Performance (Product shall be solderd on the glass-epoxy substrate (t=1.6mm).)
No. Item Specifications Test Method
9.1 Temperature
Cycle
Meet Table 1. 1 cycle
1 step : -40 °C (+0, -3)°C / 30min (+ 3,- 0) min
2 step : Ordinary temp. / 3 min max.
3 step : +105 °C (+3, -0)°C / 30min (+ 3,- 0) min
4 step : Ordinary temp. / 3 min max.
Total of 100 cycles
Then measured after exposure in the room
condition for 4 to 48 hours.
9.2 Humidity Temperature : 40 ± 2 °C
Humidity : 90 to 95 %(RH)
Time : 1000 h (+48 h , -0 h)
Then measured after exposure in the room
condition for 4 to 48 hours.
9.3 Humidity Load
Temperature : 40 ± 2 °C
Humidity : 90 to 95 %(RH)
Test Voltage : Rated Voltage
Time : 1000 h (+48 h , -0 h)
Then measured after exposure in the room
condition for 4 to 48 hours. (ref. Item 10.)
9.4 Heat life
Temperature : 105 ± 2 °C
Test Voltage : 2times for Rated Voltage
Time : 1000 h (+48 h , -0 h)
Then measured after exposure in the room
condition for 4 to 48 hours. (ref. Item 10.)
9.5 Cold Resistance
Temperature : - 40 ± 2 °C
Time : 1000 h (+48 h , -0 h)
Then measured after exposure in the room
condition for 4 to 48 hours. (ref. Item 10.)
10. Terminal to be Tested When measuring and suppling the voltage, the following terminal is applied.
No. Item Terminal to be Tested
10.1 Impedance (|Z|)
(Measurement Terminal)
10.2 DC Resistance (Rdc)
(Measurement Terminal)
10.3 Insulation Resistance (I.R.)
(Measurement Terminal)
10.4 Withstanding Voltage
(Measurement Terminal)
10.5 Humidity Load (Supply Terminal)
10.6 Heat Life (Supply Terminal)
Terminal
Terminal
Terminal
Spec. No. JEFL243C-0025G-01 P 5/10
MURATA MFG CO.,LTD.
Reference Only
11. Impedance Frequency Characteristics (Typical)
12. Specification of Packaging
12.1. Appearance and Dimensions
*Dimension of the Cavity is measured
at the bottom side.
(in mm)
12.2. Specification of Taping
(1) Packing quantity (Standard quantity) φ180 mm reel : 700 pcs. / reel φ330 mm reel :2500 pcs. / reel
(2) Packing Method
Products shall be packaged in each embossed cavity of plastic tape and sealed with cover tape.
(3) Sprocket Hole
The sprocket holes are to the right as the tape is pulled toward the user.
(4) Spliced point
The cover tape have no spliced point.
(5) Missing components number
Missing components number within 0.1% of the number per reel or 1 pc., whichever is greater,
and are not continuous.The specified quantity per reel is kept.
12.3. Pull Strength of Plastic Tape
Plastic Tape 5 N min.
Cover Tape 10 N min.
12.4. Peeling off force of Cover Tape
0.2N to 0.7N (minimum value is typical.)
Speed of Peeling off : 300 mm / min
165 to 180 degree
F
Cover tape
Plastic tape
2.7±0.1
0.4±0.05
8.0±0.1
4.0±0.1
φ
1.5
5.5±0.1
5.5
12.0±0.2
2.0±0.05
0.1
0
5.5±0.1
1.75±0.1
Direction of feed
±0.05
Spec. No. JEFL243C-0025G-01 P 6/10
MURATA MFG CO.,LTD.
Reference Only
12.5. Dimensions of Leader-tape, Trailer and Reel
There shall be leader-tape (cover tape only and empty tape) and trailer-tape (empty tape) as follows.
« Packaging Code : L (φ180mm reel) »
« Packaging Code : K (φ330mm reel) »
12.6 Marking for reel
Customer part number, MURATA part number, Inspection number(1), RoHS marking(2), Quantity, etc
1) « Expression of Inspection No. » □□
OOOO ×××
(1) (2) (3)
(1)
Factory Code
(2) Date First digit : Year / Last digit of year
Second digit : Month / Jan. to Sep. 1 to 9, Oct. to Dec. O,N,D
Third, Fourth digit : Day
(3) Serial No.
2) « Expression of RoHS marking » ROHS – Y
()
(1) (2)
(1)
RoHS regulation conformity parts.
(2) MURATA classification number
12.7 Marking for Outside package
Customer name Purchasing Order Number, Customer Part Number, MURATA part number,
RoHS marking (2), Quantity, etc
12.8 Specification of Outer Case
Reel
Outer Case Dimensions
(mm)
Standard Reel
Quantity in
Outer Case
(Reel)
WDH
φ180mm
186 186 93
4
φ330mm
340 340 85
4
Above Outer Case size is typical. It depends on a quantity of an order.
13.
!
Caution
13.1. Mounting Direction
Mount products in right direction.
Wrong direction which is 90 ° rotated from right direction cause not open or short circuit but also flames
or other serious trouble.
right direction
wrong direction
Z
Z
160 min.
210 min.
190 min.
φ
13.0±0.2
φ
21.0±0.8
φ
180±
φ
60±
13±
17±1.4
1
0
0
3
Direction of feed
Trailer
1
0
Leader
Empty Tape
Cover tape
(in mm)
Label
2.0±0.5
2.0±0.5
φ
13.0±0.5
φ
21.0±0.8
φ
330±2.0
φ
50 min.
14±1.5
2.0±0.5
(in mm)
210 min.
190 min.
Leader
Empty Tape
Cover tape
Direction of feed
Trailer
160 min.
Label
W
D
Label
H

DLW5BTM251TQ2L

Mfr. #:
Manufacturer:
Description:
Common Mode Filters / Chokes 5000mA 5.0x3.6mm DCR0.014ohm+/-40%
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: