FETA-2
FETA2500BA
AC-DC Power Supplies Enclosed Type
FE T A 2500 B A -OO -O
Ordering information
1 Series name
2 External form
T:Terminal block interface
3 Single output
4 Output wattage
5 200/230V input
6 Version
7 Output voltage
8 Optional
F2
: Reverse air exhaust
R:
w
ith Remote ON/OFF
Positive logic control
R
1 2 3 4 5 6 7 8
MODEL FETA2500BA-36 FETA2500BA-48
MAX OUTPUT WATTAGE[W]
*1
1980 2496
DC OUTPUT 36V 55A 48V 52A
SPECIFICATIONS
MODEL FETA2500BA-36 FETA2500BA-48
INPUT
VOLTAGE[V] AC170 - 264 1f (Output derating is required at AC170V - 180V. Refer to instruction manual 4.2)
CURRENT[A]
ACIN 200V
11.3typ
FREQUENCY[Hz] 50 / 60 (47 - 63)
EFFICIENCY[%]
ACIN 230V
80typ (Io=10%) 83typ (Io=10%)
87typ (Io=20%) 89typ (Io=20%)
91typ (Io=50%) 92.5typ (Io=50%)
90typ (Io=100%) 91.5typ (Io=100%)
POWER FACTOR
ACIN 230V
0.98typ (Io=100%)
INRUSH CURRENT[A]
ACIN 200V
*2
20max / 60max (Primary inrush current /Secondary inrush current) (More than 10 sec. to re-start)
LEAKAGE CURRENT[mA]
0.85max (ACIN 240V 60Hz, Io=100%, According to IEC60950-1)
OUTPUT
VOLTAGE[V] 36 48
CURRENT[A]
ACIN 170V-180V
Output derating is required at ACIN 180V or less (refer to instruction manual 4.2)
ACIN 180V-264V
55 52
LINE REGULATION[mV] 144max 192max
LOAD REGULATION[mV] 360max 480max
RIPPLE[mVp-p]
0 to +50C
*3
300max 360max
-10 to 0C
*3
360max 480max
RIPPLE NOISE[mVp-p]
0 to +50C
*3
360max 480max
-10 to 0C
*3
480max 600max
TEMPERATURE REGULATION[mV]
0 to +50C
360max 480max
-10 to +50C
440max 600max
DRIFT[mV]
*
4
144max 192max
START-UP TIME[s]
1.7max (ACIN 200V, Io=100%)
HOLD-UP TIME[ms]
ACIN 200V
10typ (Io=100%)
20typ (Io=50%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
*5
28.80 - 39.60 38.40 - 52.80
*
6
OUTPUT VOLTAGE SETTING[V]
36.00 - 37.44 48.00 - 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Activate over 105% - 120% of rated current and recovers automatically.
(Output voltage shuts down when the output voltage continuously drops due to overcurrent protection.)
*
7
OVERVOLTAGE PROTECTION[V]
*7
42.00 - 45.00 56.00 - 60.00
DC_OK LAMP
LED (Green)
ALARM LAMP LED (Amber)
REMOTE ON/OFF Provided
ISOLATION
INPUT
-
OUTPUT-AUX-RC-WRN-PG
AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature)
INPUT
-
FG AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature)
OUTPUT-AUX-RC-WRN-PG
-
FG
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
OUTPUT
-
AUX-RC-WRN-PG
AC100V 1minute, Cutoff current = 100mA, DC100V 50MW min (At room temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +85C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s
2
(2G), 3minutes period, 60minutes each along X, Y and Z axis
IMPACT 196.1m/s
2
(20G), 11ms, once each along X, Y and Z axis
SAFETY AND
NOISE REGULATIONS
AGENCY APPROVALS UL60950-1, C-UL (CSA60950-1), EN60950-1
CONDUCTED NOISE Complies with FCC Part15-A, CISPR22-A, EN55011-A, EN55022-A, VCCI-A
HARMONIC ATTENUATOR Complies with IEC61000-3-2 Class A
*
8
OTHERS
CASE SIZE/WEIGHT
*9
102X41X340mm [4.02X1.61X13.39 inches] (WXHXD) / 2.3kg max
COOLING METHOD Forced cooling (internal fan)
*1 AUX output power is not included.
*2
The current of input surge to a b
uilt-in noise filter (0.2ms or less) is excluded.
*3
Measured b
y 500MHz oscilloscope.
Ripple and r
ipple noise is measured on measuring board with capacitor of 22mF within
150mm from the output terminal.
*4
Dr
ift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*5
Can not be used abo
ve the rated output current and the rated output power.
*6 When the output voltage is adjusted to higher than 49.92V and the load factor is over 70%
of the rated current, if the load current changes quickly (< 200msec), the output voltage
drops approximately 5V below the setting voltage.
*7 Output voltage recovers from protection by shutting down the input voltage and waiting
more than 10 seconds then turning on AC input again, or turning off the output voltage by
remote control.
*8
Please contact us about another class
.
*9 Case size contains neither the terminal blocks, connector and screw nor.
*
T
o meet the specifications. Do not operate over-loaded condition.
*
A sound ma
y occur from power supply at peak loading.
Example recommended EMI/EMC filter
NAC-20-472
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
High voltage pulse noise type : NAP series
Low leakage current type : NAM series