04-2015, Rev. 0415
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
SCHRACK
General Purpose Relays
PCB Relays
Power PCB Relay RT1 Inrush
n
1 pole 16A, 1 form C (CO) or 1 form A (NO) contact
n
For inrush peak currents up to 80A
n
Mono- or bistable coil
n
5kV/10mm coil-contact
n
Reinforced insulation
n
Ambient temperature 85°C
n
WG version: product in accordance to IEC 60335-1
Typical applications
Domestic appliances, heating control, lighting control
Approvals
VDE Cert. No. 40007571, UL E214025, cCSAus 1142018
Technical data of approved types on request
Contact Data
Contact arrangement 1 form C (CO) or 1 form A (NO)
Rated voltage 250VAC
Max. switching voltage 400VAC
Rated current 16A
Limiting continuous current 16A, UL: 20A (K-version)
Limiting making current,
max. 4s, df 10% 30A
max. 20ms (incandescent lamps), RT33L version
80A
Breaking capacity max. 4000VA
Contact material AgNi90/10, AgSnO
Frequency of operation, with/without load 360/72000h
-1
Operate/release time max., DC coil 9/6ms
Operate/Reset time max., bistable version 10/10ms
Bounce time max., form A/form B 3/6ms
Contact ratings
Type Contact Load Cycles
IEC 61810
RT33L A (NO) 16A, 250VAC resistive, 85°C 50x10
3
RT33L A (NO) 10A, 400VAC resistive, 85°C 10x10³
RT31 C (CO) 16A, 250VAC resistive, 85°C 6x10³
RT33K A (NO) 16A, 250VAC resistive, 85°C 30x10
3
UL 508
RT33K A (NO) 20A, 277VAC general purpose, 40°C 10x10
3
RT33L A (NO) 16A, 250VAC resistive, 85°C 50x10
3
RT31 C (CO) 16A, 250VAC resistive, 85°C 6x10³
RT33L A (NO) 1000W Tungsten, 120VAC, 60 Hz, 40°C 6x10
3
RT33L A (NO) 1000W standard ballast,
120VAC, 60 Hz, 40°C 6x10
3
Mechanical endurance
monostable version >30x106 operations
bistable version >5x106 operations
Coil Data, DC coil
Coil voltage range 5 to 110VDC
Operative range, IEC 61810 2
Coil insulation system according UL class F
Coil versions, DC coil
Coil Rated Operate Release Coil Rated coil
code voltage voltage voltage resistance power
VDC VDC VDC Ω±10%
1)
mW
005 5 3.5 0.5 62 403
006 6 4.2 0.6 90 400
012 12 8.4 1.2 360 400
024 24 16.8 2.4 1440 400
048 48 33.6 4.8 5520 417
060 60 42.0 6.0 8570
1)
420
1) Coil resistance ±12%.
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Coil Data, bistable coils 1 coil 2 coils
Magnetic system polarized, bistable
Coil voltage range 5 to 24VDC
Operative range, IEC 61810 2
Limiting voltage, % of rated coil voltage 120% 150%
Min./Max. energization duration 30ms/1min at <10% duty factor
Coil insulation system according UL class F
F0177-C