ICS343
FIELD PROGRAMMABLE TRIPLE OUTPUT SS VERSACLOCK SYNTHESIZER EPROM CLOCK SYNTHESIZER
IDT® / ICS™
FIELD PROGRAMMABLE TRIPLE OUTPUT SS VERSACLOCK SYNTHESIZER 6
ICS343 REV M 090613
AC Electrical Characteristics
Unless stated otherwise, VDD = 3.3V ±5%, Ambient Temperature -40 to +85 C
Note 1: Measured with 15 pF load.
Note 2: Duty Cycle is configuration dependent. Most configurations are minimum 45% and maximum 55%.
Note 3: ICS test mode output occurs for first 170 clock cycles on CLK3 for each PLL powered up.
Thermal Characteristics
Parameter Symbol Conditions Min. Typ. Max. Units
Input Frequency F
IN
Fundamental Crystal 5 27 MHz
Input Clock 2 50 MHz
Output Frequency 0.25 200 MHz
Output Rise Time t
OR
20% to 80%, Note 1 1 ns
Output Fall Time t
OF
80% to 20%, Note 1 1 ns
Duty Cycle Note 2 40 49-51 60 %
Output Frequency Synthesis
Error
Configuration Dependent TBD ppm
Power-up time PLL lock time from
power-up, Note 3
410ms
PDTS
goes high until
stable CLK output, Spread
Spectrum Off, Note 3
0.2 2 ms
PDTS
goes high until
stable CLK output, Spread
Spectrum On, Note 3
47ms
One Sigma Clock Period Jitter Configuration Dependent 50 ps
Maximum Absolute Jitter t
ja
Deviation from Mean.
Configuration Dependent
+200 ps
Parameter Symbol Conditions Min. Typ. Max. Units
Thermal Resistance Junction to
Ambient
JA
Still air 150 C/W
JA
1 m/s air flow 140 C/W
JA
3 m/s air flow 120 C/W
Thermal Resistance Junction to Case
JC