Inductive Proximity Sensors
(Wiring Schematic)
3 Wire DC PNP – Normally Open (1) - - - - -
PNP – Normally Closed (1) - - - - -
PNP – Selectable (4) - - - - -
NPN – Normally Open (2) - - - - -
NPN – Normally Closed (2) - - - - -
NPN – Selectable (5) - - - - -
2 Wire DC Normally Open (6) IMM42185C IMM45188C IMN42185M12 IMN45188M12 -
Normally Closed (6) IMM43185C IMM46188C IMN43185M12 IMN46188M12 -
2 Wire AC
- - - - IMM62185C
Normally Closed (7) - - - - IMM63185C
Mating cables / connectors
Form M18 Shielded M18 Non-Shielded M18 Shielded M18 Non-Shielded M18 Shielded
Nominal Sensing Distance (Sn) 5mm 8mm 5mm 8mm 5mm
Housing Material
Nickel Plated Brass
Termination Type 2.0 Meter Cable 2.0 Meter Cable M12 Connector M12 Connector 2.0 Meter Cable
Min / Max Supply Voltage 10 to 30Vdc 20 to 220 Vac
Max. Load Current (Ir) 100mA 400 mA
Max ripple factor (Vr)
≤ 10%
-
Voltage Drop (Ud)
Power Consumption (Io) ≤ 0.7mA ≤ 2.5mA
Switching Frequency (Hz) 700 Hz 400 Hz 700 Hz 400 Hz 20 Hz
Repeatability < 2% nominal sensing distance
Hysteresis ≤ 10% Sn
Short Circuit Protection Yes No
Output LED Yes Yes
Operating Temperature -25 to +70 C
IP Rating IP67 (with connector mounted)
Wiring Diagram
≤ 7 Vdc ≤ 4.5Vac
For Technical Assistance and / or Customer Service, call 800/677-5311, www.crouzet-usa.com
M18 Inductive Proximity Sensors
Standard Length
“Mini's”
Extended Sensing
3 Wire DC
2 Wire DC