RV-3.305D/P/R8

2 Watt DIP24
Miniature
Single
& Dual
Output
UL/CSA and EN-60950-1 Safety certified
EN-61010 for Test, Measurement and Lab Use
UL/CSA and EN-60601 for Medical Applications
6.4kVDC or 8kV Reinforced Isolation
Optional Continuous Short Circuit Protection
Efficiency to 88%
Space Saving „Skinny DIP“ Package
Very Low Isolation Capacitance
Features
Unregulated
Converters
Selection Guide
Output Power (%)
100
60
20
40
100500-40
85
150
Operating Temperature °C
0
80
Safe Operating Area
Derating-Graph
(Ambient Temperature)
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 3.3V output types 20% max.
(10% to 100% full load) 5V output type 15% max.
9V, 12V, 15V, 24V output types 10% max.
Output Ripple and Noise (20MHz limited) 200mVp-p max.
Operating Frequency 20kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load 70% min. / 75% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage /R6.4 (tested for 1 second) 6400VDC
(rated for 1 minute**) 3200VAC / 60Hz
/R8 (tested for 1 second) 8000VDC
(rated for 1 minute**) 4000VAC / 60Hz
Isolation Capacitance 2pF min. / 12pF max.
Isolation Resistance 15 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
continuned on next page
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Description
Very high isolation in a small size are the main features of this miniature DIP24 converter,
ideal for highly sophisticated industrial, test and measurement and medical designs where
board space is at a premium.
RV/R
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Refer to Application Notes
E-314885
Part Reinforced Input Output Output Efficiency Max
Number Isolation Voltage Voltage Current Std Capacitive
SIP 7 (kVDC) (VDC) (VDC) (mA) (%) Load
(1)
RV-xx3.3S /R6.4 & /R8 3.3, 5, 12, 15, 24 3.3 600 70-78 3300µF
RV-xx05S /R6.4 & /R8 3.3, 5, 12, 15, 24 5 400 76-80 1200µF
RV-xx09S /R6.4 & /R8 3.3, 5, 12, 15, 24 9 222 78-85 1200µF
RV-xx12S /R6.4 & /R8 3.3, 5, 12, 15, 24 12 167 78-85 680µF
RV-xx15S /R6.4 & /R8 3.3, 5, 12, 15, 24 15 132 78-88 680µF
RV-xx3.3D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±3.3 ±300 70-78 ±1500µF
RV-xx05D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±5 ±200 75-82 ±470µF
RV-xx09D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±9 ±111 76-84 ±470µF
RV-xx12D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±12 ±85 78-86 ±220µF
RV-xx15D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±15 ±66 78-86 ±220µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
RV-0505S/P, RV-0505D/P
* add Suffix “/R6.4”or “/R8” for Reinforced Isolation, e.g. RV-0505S/R6.4, RV-0505D/P/R8
For functional isolation, please refer to RV sereis datasheet
EN-60950-1 Certified
EN-60601-1 Certified
UL/CSA 60950-1 Certified
UL-60601-1 Certified
EN-61010-1 Certified
IEC-60601-1 CB Report
RoHS
2011/65/EU
6/6
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
REV: 3/2016 E-113www.recom-power.com
RV /R
ECONOLINE
DC/DC-Converter
Relative Humidity 95% RH
Package Weight 9g
Packing Quantity 15 pcs per Tube
MTBF (+25°C) using MIL-HDBK 217F 1154 x 10
3
hours
(+85°C) using MIL-HDBK 217F 168 x 10
3
hours
Reinforced Isolation Transformer Creepage Reinforced Types 5.5 mm min.
Transformer Clearance Reinforced Types 5.5 mm min.
PCB Creepage & Clearance Reinforced Types 9.6 mm min.
Certifications
Measurement, Control and Laboratory Use Safety Report: T1301251-313 EN 61010-1 : 2010
CSA General Safety UL 60950-1 1st Edition
C22.2 No. 60950-1-03
UL/cUL Medical Safety Report: E314885-A4 UL60601-1 3rd Edition
CSA Medical Safety Report: 2207629 CAN/CSA-22.2 No 601.1-M90
EN General Safety Report: SPCLVD1310079-1 EN60950-1 : 2006
EN Medical Safety Report: CA-10168-A1-UL IEC/EN 60601-1 3rd Edition
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Tolerance Envelope
+10%
+6%
V Nom.
+5%
 2.5%
10% 50% 100%
Output Voltage
Output Load Current (%)
 5%
Typical Load Line
}
Detailed Information see
Application Notes chapter "MTBF"
Notes
Note 1 Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter.
RV/R
Series
REV: 3/2016 www.recom-power.comE-114
RV/R
Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
RV-1205D/R6.4
RV-0505D/R6.4
RV-2405D/R6.4
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0.000
5.000
10.000
15.000
20.000
25.000
RV-1205D/R6.4
RV-0505D/R6.4
RV-2405D/R6.4
RV-xx05D/R6.4 and RV-xx05D/R8
RV/R
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
RV-1205S/R6.4
RV-0505S/R6.4
RV-2405S/R6.4
Deviation / Load
-10.000
40%0% 100%
Deviation from Nominal (%)
60%
80%
20%
-5.000
Total Output current (%)
0.000
5.000
10.000
15.000
20.000
25.000
RV-1205S/R6.4
RV-0505S/R6.4
RV-2405S/R6.4
RV-xx05S/R6.4 and RV-xx05S/R8
REV: 3/2016 E-115www.recom-power.com
EN55022 Class A
+
Output
Input
C2
C1
C1 C2
RxxP2xx/R6.4 10μF
2n2F 8kV
Vishay HGZ222MBP
RxxP2xx/R8 10μF
2n5F 10kV
Vishay HGZ222MBP
EMC Filter Suggestions for EN55022 Class A and B

RV-3.305D/P/R8

Mfr. #:
Manufacturer:
RECOM Power
Description:
Isolated DC/DC Converters 2W DC/DC MIN 8kV UNREG 3.3Vin +/-5out
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union