Derating-Graph
(Ambient Temperature)
Input Voltage Range ±10%
Output Voltage Accuracy ±5%
Line Voltage Regulation 1.2%/1% of Vin typ.
Load Voltage Regulation 3.3V output types 20% max.
(10% to 100% full load) 5V output type 15% max.
9V, 12V, 15V, 24V output types 10% max.
Output Ripple and Noise (20MHz limited) 200mVp-p max.
Operating Frequency 20kHz min. / 50kHz typ. / 85kHz max.
Efficiency at Full Load 70% min. / 75% typ.
Minimum Load = 0% Specifications valid for 10% minimum load only.
Isolation Voltage /R6.4 (tested for 1 second) 6400VDC
(rated for 1 minute**) 3200VAC / 60Hz
/R8 (tested for 1 second) 8000VDC
(rated for 1 minute**) 4000VAC / 60Hz
Isolation Capacitance 2pF min. / 12pF max.
Isolation Resistance 15 GΩ min.
Short Circuit Protection 1 Second
P-Suffix Continuous
Operating Temperature Range (free air convection) -40°C to +85°C (see Graph)
Storage Temperature Range -55°C to +125°C
continuned on next page
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
Description
Very high isolation in a small size are the main features of this miniature DIP24 converter,
ideal for highly sophisticated industrial, test and measurement and medical designs where
board space is at a premium.
RV/R
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Refer to Application Notes
E-314885
Part Reinforced Input Output Output Efficiency Max
Number Isolation Voltage Voltage Current Std Capacitive
SIP 7 (kVDC) (VDC) (VDC) (mA) (%) Load
(1)
RV-xx3.3S /R6.4 & /R8 3.3, 5, 12, 15, 24 3.3 600 70-78 3300µF
RV-xx05S /R6.4 & /R8 3.3, 5, 12, 15, 24 5 400 76-80 1200µF
RV-xx09S /R6.4 & /R8 3.3, 5, 12, 15, 24 9 222 78-85 1200µF
RV-xx12S /R6.4 & /R8 3.3, 5, 12, 15, 24 12 167 78-85 680µF
RV-xx15S /R6.4 & /R8 3.3, 5, 12, 15, 24 15 132 78-88 680µF
RV-xx3.3D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±3.3 ±300 70-78 ±1500µF
RV-xx05D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±5 ±200 75-82 ±470µF
RV-xx09D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±9 ±111 76-84 ±470µF
RV-xx12D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±12 ±85 78-86 ±220µF
RV-xx15D /R6.4 & /R8 3.3, 5, 12, 15, 24 ±15 ±66 78-86 ±220µF
xx = Input Voltage. Other input and output voltage combinations available on request.
* add Suffix “P” for Continuous Short Circuit Protection, e.g.
RV-0505S/P, RV-0505D/P
* add Suffix “/R6.4”or “/R8” for Reinforced Isolation, e.g. RV-0505S/R6.4, RV-0505D/P/R8
For functional isolation, please refer to RV sereis datasheet
EN-60950-1 Certified
EN-60601-1 Certified
UL/CSA 60950-1 Certified
UL-60601-1 Certified
EN-61010-1 Certified
IEC-60601-1 CB Report
RoHS
2011/65/EU
6/6
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.