F92ERLNSNSNM001

Opti-Core
®
Fiber Optic Patch Cords
and Pigtails
SPECIFICATION SHEET
construction
Fiber count:
Simplex (1-fiber) jacketed
Duplex (2-fiber) jacketed zipcord
Tight buffered
Cable
jacket ratings:
Riser (OFNR)
Low Smoke Zero Halogen (LSZH) per:
IEC 60332-1-2, IEC 60332-3-24, IEC
60754-1, IEC 60754-2, IEC 61034-2
Fiber types:
Singlemode: OS1/OS2 9/125µm
Multimode: OM1 62.5/125µm
OM2 50/125µm
OM3 50/125µm
OM4 50/125µm
Connector
types end ‘A’:
Simplex or duplex LC, SC
Jacket color:
OS1/OS2: Yellow
OM1: Orange
OM2: Orange
OM3: Aqua
OM4: Aqua
Buffered fiber (pigtail): Blue
Connector
types end ‘B’:
Simplex or duplex LC, SC
application
Provide interconnect and cross-connect of applications in entrance facilities, telecommunications rooms, data centers, at the
desk and network applications to interconnect pre-terminated cassettes in main distribution, horizontal distribution, and
equipment distribution areas.
technical information
Fiber optic patch cords and pigtails provide interconnect and cross-connect of
applications over installations in entrance facilities, telecommunications rooms, data
centers and at the desk. Patch cords support network applications in main, horizontal
and equipment distribution areas and are available in riser (OFNR), and low smoke
zero halogen (LSZH) rated jacket materials to comply with local cabling ordinances.
Pre-terminated fiber optic pigtails support fusion splice field termination applications.
Fiber optic patch cords and pigtails are available in OM4, OM3, OM2, OM1, or OS1/
OS2 fiber types to meet the demands of Gigabit Ethernet, 10 Gigabit Ethernet and high
speed Fibre Channel.
physical properties
Cable outside diameter (OD):
1.6mm duplex
3mm simplex
900 micron
Connector cable retention:
50N @ 0°C
19.4N @ 90°C
Connector durability:
500 cycles
Bend radius, minimum:
1.6mm: 16mm
3mm: 29mm
optical properties
Connector
insertion loss:
0.25dB max. (Multimode - Standard IL)
0.15db max. (Multimode - Optimized IL)
0.10db max. (Multimode - Ultra IL)
0.35dB max. (LC singlemode)
0.50dB max. (SC singlemode)
Connector
return loss:
20dB min. (OM1 and OM2)
26dB min. (OM3 and OM4)
55dB min. (OS1/OS2)
environmental properties
Storage and
shipping temperature:
-40°C to 70°C
Operating and
installation temperature:
Riser: -20°C to 70°C
Plenum: 0°C to 60°C
www.panduit.com
standards
Meets or exceeds ISO/IEC 11801, TIA/EIA-568-C.3,
TIA-604-3 (FOCIS-3), TIA-604-10 (FOCIS-10)
Restriction of Hazardous
Substances
(RoHS) Compliance:
All patch cord components
meet the requirements of
Directive 2002/95/EC.
Note: For hybrid cords, the SC connector is always on End B.
Opti-Core
®
Fiber Optic Patch Cords and Pigtails
1 2 3 4 5 6 7 8 9 10 11 12
13
14
15
F Z 2 E R L N S N S N M
0
0
5
1 – Fiber Product
F = Fiber
2 – Fiber Type
6 = OM1 62.5/125µm
5 = OM2 50/125µm
X = OM3 50/125µm
Z = OM4 50/125µm
9 = OS1/OS2 9/125µm
3 – Fiber Count
1 = 1 fiber
2 = 2 fibers
4 – Cable Type
B = 900µm buffer
E = 1.6mm
3 = 3.0mm (For SC to SC cords)
5 – Jacket Type
L = LSZH (Low Smoke Zero Halogen)
N = (No Jacket) 900µm Buffered Fiber
R = OFNR (Riser)
6 – Connector Type - End A
1 = LC
3 = SC
L = LC duplex
S = SC duplex
7 – Connector Variant
N = No variant
8 – Connector Type - End B
1 = LC
3 = SC
L = LC duplex
N = None; pigtail
S = SC duplex
9 – Connector Variant
N = No variant
10 – Performance/Construction
S = Standard IL (A-B)
O = Optimized (A-B)
N = Ultra (A-B)
11 – Other
N = No variant
12 – Unit of Length
M = Meters
13, 14, 15 – Length
001-050
Character
Example
part number
©2016 Panduit Corp.
ALL RIGHTS RESERVED.
FBSP54--WW-ENG
4/2016
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
PANDUIT CANADA
Markham, Ontario
cs-cdn@panduit.com
Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK
cs-emea@panduit.com
Phone: 44.20.8601.7200
PANDUIT JAPAN
Tokyo, Japan
cs-japan@panduit.com
Phone: 81.3.6863.6000
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
cs-ap@panduit.com
Phone: 65.6305.7575
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
cs-aus@panduit.com
Phone: 61.3.9794.9020
PANDUIT LATIN AMERICA
Guadalajara, Mexico
cs-la@panduit.com
Phone: 52.33.3777.6000
Contact Customer Service by email: cs@panduit.com
or by phone: 800.777.3300
Visit us at www.panduit.com
For more information
fiber optic patch cord detail
Other options are available as follows; contact Panduit for part number:
Fiber Type: OM4+(50/125µm Signature Core
)
Cable Type: 3.0mm
Jacket Type: OFNG (General Rated)
Connector Type: ST, FC, SC/APC, E2000, MTRJ Female, FJ Jack Keyed, FJ Plug Keyed, LC Keyed, FJ Jack, FJ Plug, MTRJ Male
Performance/Construction: Optimized IL – Straight Thru (A-B), Optimized IL – Flipped (A-A), Standard IL – Flipped (A-A)
Other: Non-standard colored cable
Patch Cord Length
Example: FZ2ERLNSNSNM005 = Fiber OM4, 2-fiber, 1.6mm cable, riser rated, LC duplex to SC duplex, standard IL, 5 meters
Note: For hybrid cords, the SC connector is always on End B.