TL-M5ME1

1
CSM_TL-M_DS_E_3_1
Compact Proximity Sensor
TL-M
As Easy To Install as a Microswitch
• A compact Proximity Sensor with the feel of a microswitch.
Be sure to read Safety Precautions on
page 4.
Ordering Information
Note: Models with different frequencies are also available. The model numbers are TL-M@M@@5 (e.g., TL-M2ME15).
Ratings and Specifications
Appearance Sensing distance Output specifications
Model
Operation mode
NO NC
DC 3-wire, NPN voltage output TL-M2ME1 2M TL-M2ME2 2M
AC 2 wire TL-M2MY1 2M ---
DC 3-wire, NPN voltage output TL-M5ME1 2M TL-M5ME2 2M
AC 2 wire TL-M5MY1 2M ---
Item Model TL-M2ME1, TL-M2ME2, TL-M2MY1 TL-M5ME1, TL-M5ME2, TL-M5MY1
Sensing distance 2 mm ±10% 5 mm ±10%
Set distance 0 to 1.6 mm 0 to 4 mm
Differential travel 10% max. of sensing distance
Detectable object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 2.)
Standard sensing object Iron, 15 × 15 × 1 mm
Response frequency E Models: 500 Hz, Y Models: 20 Hz E Models: 250 Hz, Y Models: 20 Hz
Power supply voltage
(operating voltage range)
E Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 20% max.
Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
Current consumption E Models: 15 mA max. at 24 VDC (no-load)
Leakage current Y Models: 2.5 mA max. at 200 VAC
Control
output
Load current
E Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC
Y Models: 10 to 200 mA
Residual
voltage
E Models: 1 V max.
Y Models: Refer to Residual Output Voltage under Engineering Data on page 3.
Indicators
E Models: Detection indicator (red)
Y Models: Operation indicator (red)
Operation mode (with sens-
ing object approaching)
E1/Y1 Models: NO
E2 Models: NC
Protection circuits
E Models: Reverse polarity protection, Surge suppressor
Y Models: Surge suppressor
Ambient temperature range Operating/Storage: 25 to 70°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Microswitch
type
2 mm
5 mm
Refer to the timing charts under I/O Circuit Diagrams on page 3 for details.
TL-M
2
Engineering Data (Typical)
Item Model TL-M2ME1, TL-M2ME2, TL-M2MY1 TL-M5ME1, TL-M5ME2, TL-M5MY1
Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C
Voltage influence
E Models: ±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
Y Models: ±1% max. of sensing distance at rated voltage in the rated voltage ±10% range
Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
E Models: 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s
2
10 times each in X, Y, and Z directions
Degree of protection IEC 60529 IP67, in-house standards: oil-resistant
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 75 g
Materials
Case
Heat-resistant ABS
Sensing surface
Accessories Instruction manual
Sensing Area Leakage Current
TL-M2@/M5@ TL-M@MY1
Influence of Sensing Object Size and Material
TL-M2ME TL-M2MY1 TL-M5M
X
6
5
4
3
2
1
0
468
Y
864202
TL-M5M
Standard sensing
object
Iron, 15 × 15
t = 1 mm
TL-M2M
Standard
sensing
object
Iron, 12 × 12
t = 1 mm
Distance X (mm)
Sensing Head
Distance Y
(mm)
3
2
100 15090
0
1
6
5
4
A
250200
Power supply voltage (V)
Protective resistance
AC power
Leakage current (mA)
1.0
0.5
0
2.5
2.0
1.5
5040302010
X
d ×
d
t
= 1 mm
Side length of sensing object: d (mm)
Stainless steel
(SUS304)
Note: Does not operate for brass or aluminum.
Iron
Distance X (mm)
1.0
0.5
20100
2.5
2.0
1.5
X
504030
d ×
d
t
= 1 mm
Side length of sensing object: d (mm)
Stainless steel
(SUS304)
Aluminum
Iron
Brass
Distance X (mm)
2
1
100
6
5
4
3
6050403020
X
d ×
d
t
= 1 mm
Side length of sensing object: d (mm)
Stainless steel (SUS304)
Aluminum
Iron
Brass
Distance X (mm)
TL-M
3
I/O Circuit Diagrams
DC 3-Wire Models
AC 2-Wire Models
Residual Output Voltage
TL-M@MY1 at 100 VAC TL-M@MY1 at 200 VAC
Operation
mode
Output specifi-
cations
Model Timing chart Output circuit
NO
NPN
TL-M2ME1
TL-M5ME1
NC
TL-M2ME2
TL-M5ME2
100 VAC
A
50
V
ON
100
0105 20050 100 150
OFF
Load current (mA)
Residual output
voltage
Residual
load
voltage
Load voltage V
L
(V)
50
010 505
OFF
200100 150
V
A
200 VAC
ON
Load current (mA)
20
Residual Output
Voltage
Residual
load
voltage
Load voltage VL (V)
Sensing object
Present
None
Load (between brown
and black leads)
Operate
Reset
Output voltage (between
black and blue leads)
High
Low
Detection indicator (red)
ON
OFF
*1. 200 mA max. (load current).
*2. When a transistor is connected.
100
4.7 k
2.2
*2
0 V
Tr
+V
*1
Load
Brown
Black
Blue
Output
Prox-
imity
Sensor
main
circuit
Sensing object
Present
None
Load (between brown
and black leads)
Operate
Reset
Output voltage (between
black and blue leads)
High
Low
Detection indicator
(Red)
ON
OFF
Operation
mode
Model Timing chart Output circuit
NO
TL-M2MY1
TL-M5MY1
Sensing object
Present
None
Load
Operate
Reset
Operation indicator
(Red)
ON
OFF
Prox-
imity
Sensor
main
circuit
Load
Blue
Brown

TL-M5ME1

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
Proximity Sensors TLM5ME1
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union