PA-1
REV.: 3/2016www.recom-power.com
AC/DC Converter
3
Y
E
A
R
w
a
r
r
a
n
t
y
3
Specifications (measured at T
A
= 25°C, nominal input voltage, full load and after warm-up)
BASIC CHARACTERISTICS
Parameter Condition Min. Typ. Max.
Input Voltage Range
80VAC
113VDC
277VAC
390VDC
305VAC
430VDC
Input Current
full load, 115VAC
full load, 230VAC
98mA
64mA
Inrush Current
cold start at 25°C, 115VAC
cold start at 25°C, 230VAC
15A
30A
No load Power Consumption 80-305VAC, 50/60Hz 50mW
Input Frequency Range AC Input 47Hz 440Hz
Hold-up time 115VAC 15ms
continued on next page
Description
The RAC04-xxS_DC/277 series are fully certified single and dual regulated AC/DC converters in an encapsulated
PCB-mount package style with 3.75kVAC isolation and very low stand-by power consumption. The modules are
suitable for worldwide use due to their wide input voltage range from 80VAC to 305VAC. Possible uses include
home automation, standby applications and industrial controls.
Features
Regulated
Converters
• 50mW max. No Load Power Consumption
• High Efficiency up to 79%
• Isolated Output 3.75kVAC / 1 min
• SCP, OVP Protection
• Wide Operating Temperature Range:
-40°C to +80°C (only with suffix „-E“)
• Universal Input 80-305VAC
4 Watt
Single and
Dual Output
RAC04-C/277
Selection Guide
Part Input Output Output Efficiency Max. Capacitive
Number Voltage Range Voltage Current typ. Load
(1+2)
(VAC) (VDC) (mA) (%) (µF)
RAC04-3.3SC/277
(3)
80-305 3.3 1200 72 10000
RAC04-05SC/277
(3)
80-305 5 800 75 7200
RAC04-12SC/277
(3)
80-305 12 333 78 1000
RAC04-15SC/277
(3)
80-305 15 267 79 820
RAC04-24SC/277
(3)
80-305 24 167 79 220
RAC04-0512DC/277
(3)
80-305 5/12 720/33 75 4700/100
RAC04-05DC/277
(3)
80-305 ±5 ±400 76 ±3300
RAC04-12DC/277
(3)
80-305 ±12 ±166 78 ±680
IEC-60950-1 Certified
EN-55024 Certified
EN-60950-1 Certified
UL-60950-1 Certified
E224736
Output Voltage
Single or Dual
RAC04-__ _C/277 -_
Notes:
Note3: with suffix “-E” for -40°C to +80°C operating temperature range
without suffix standard operating temperature range (-25°C to +80°C)
Notes:
Note1: Measured @ 230VAC/50Hz/Ta 25°C with constant resistant mode at full load.
Note2: If used @115VAC/60Hz with full load, max. capacitive load is less, please contact
RECOM for detailed information.
Temperature
(3)
Ordering Examples:
e.g. RAC04-3.3SC/277-E, Single Output, with -40° to +80°C operating temperature range
e.g. RAC04-05DC/277, Dual Output with standard operating temperature range
Model Numbering