HRP-600-24

Universal AC input / Full range
Built-in active PFC function, PF>0.94
High efficiency up to 89%
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage / Over temperature
Built-in constant current limiting circuit
Built-in cooling fan ON-OFF control
DC OK signal Built-in
Built-in remote sense function
All using 105 long life electrolytic capacitors
5 years warranty
SPECIFICATION
HRP-600-3.3 HRP-600-5 HRP-600-7.5 HRP-600-12 HRP-600-15 HRP-600-24 HRP-600-36 HRP-600-48
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.) Note.2
OUTPUT VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
PROTECTION
AC CURRENT (Typ.)
3.3V 5V 7.5V 12V 15V 24V 36V 48V
120A
120A 80A 53A 43A 27A 17.5A 13A
0 ~ 120A 0 ~ 120A 0 ~ 80A 0 ~ 53A 0 ~ 43A 0 ~ 27A 0 ~ 17.5A 0 ~ 13A
396W 600W 600W 636W 645W 648W 630W 624W
100mVp-p 100mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 200mVp-p 240mVp-p
2.8 ~ 3.8V 4.3 ~ 5.8V 6.8 ~ 9V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V 28.8 ~ 39.6V 40.8 ~ 55.2V
±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.3% ±0.3% ±0.2% ±0.2% ±0.2%
±1.0% ±1.0% ±1.0% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
1600ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
16ms/230VAC 16ms/115VAC at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.94/230VAC PF>0.99/115VAC at full load
78.5% 82%
6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 41.4 ~ 48.6V 57.6 ~ 67.2V
87% 88% 88% 88% 89% 89%
7.6A/115VAC 3.6A/230VAC
35A/115VAC 70A/230VAC
<1.2mA / 240VAC
105 ~ 135% rated output power
3.96 ~ 4.62V
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
UL60950-1, TUV EN60950-1 EAC TP TC 004 approved
,
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteria A, EAC TP TC 020
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
-40 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
140.6K hrs min. MIL-HDBK-217F (25 )
218*105*63.5mm (L*W*H)
Features :
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
HRP-600 series
600W Single Output with PFC Function
1.5Kg;8pcs/13Kg/1.34CUFT
File Name:HRP-600-SPEC 2018-01-23
FUNCTION
DC OK SIGNAL
FAN CONTROL (Typ.)
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
Load 35 15% or RTH2 50 Fan on≧℃±
EMC IMMUNITY
EMC EMISSION
Mechanical Specification
Case No. 977A Unit:mm
AC Input Terminal Pin No.
Assignment
DC Output Terminal Pin No.
Assignment
Pin No. Pin No.
1 1~3
3
2 4~6
Assignment Assignment
AC/N +V
AC/L -V
Pin No.
4
3
1
2
Assignment
-S
+S
DC-OK
GND
Mating Housing Terminal
or equivalent or equivalent
Connector Pin No. Assignment(CN100) : HRS DF11-4DP-2DS or equivalent
HRS DF11-4DS
HRS DF11-**SC
FG
Derating Curve Output Derating VS Input Voltage
INPUT VOLTAGE (V) 60Hz
85 100 125 135 155 264
100
90
80
70
60
50
40
LOAD(%)
105
18max.
119.2
O/P
1
2
3
4
5
6
AMBIENT TEMPERATURE ( )
LOAD (%)
-40010203040506070
20
50
80
100
125
(HORIZONTAL)
DC OK
600W Single Output with PFC Function
File Name:HRP-600-SPEC 2018-01-23
PWM fosc : 70KHz
O.L.P.
O.T.P.
EMI
INRUSH
ACTIVE
FILTER
CURRENT
LIMITING
RECTIFIERS
&
PFC
I/P
FG
PWMPFC
CIRCUIT
DETECTION
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
+S
CONTROLCONTROL
O.V.P.
O.T.P.
-V
-S
HRP-600 series
Air flow
direction
CN100
LED
SVR1
(VoADJ.)
63.5
3
2
1
I/P
4-M4 L=6
12max.
8.2
63.5
20.75
10
218
32.8152.4
1
2
3
4
Block Diagram
8-M4 L=4 (Both Sides)
32.8
38.312.5
152.4

HRP-600-24

Mfr. #:
Manufacturer:
Description:
Switching Power Supplies 648W 24V 27A ACTIVE PFC FUNCTION
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS