5
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics (HCPL-3020 and HCPL-0302 Option 060)
Description Symbol HCPL-3020 HCPL-0302 Unit
Installation Classication per DIN VDE 0110/1.89, Table 1
for Rated Mains Voltage 150 V
rms
I – IV I – IV
for Rated Mains Voltage 300 V
rms
I – III I – III
for Rated Mains Voltage 600 V
rms
I – II
Climatic Classication 55/100/21 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2 2
Maximum Working Insulation Voltage V
IORM
630 566 V
peak
Input to Output Test Voltage, Method b
[1]
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial Discharge < 5 pC V
PR
1181 1050 V
peak
Input to Output Test Voltage, Method a
[1]
V
IORM
x 1.5 = V
PR
, Type and Sample Test, t
m
= 60 sec,
Partial Discharge < 5 pC V
PR
945 840 V
peak
Highest Allowable Overvoltage
(Transient Overvoltage t
ini
= 10 sec) V
IOTM
6000 4000 V
peak
Safety-Limiting Values – Maximum Values Allowed in the Event of a
Failure.
Case Temperature T
S
175 150 °C
Input Current
[2]
I
S, INPUT
230 150 mA
Output Power
[2]
P
S, OUTPUT
600 600 mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
>10
9
Ω
1. Refer to the optocoupler section of the Isolation and Control Compo-
nents Designer’s Catalog, under Product Safety Regulations section,
(IEC/EN/DIN EN 60747-5-2), for a detailed description of Method a
and Method b partial discharge test proles.
2. Refer to the following gure for dependence of P
S
and I
S
on ambient
temperature.
Regulatory Information
The HCPL-0302/3020 has been approved by the following organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
(Option 060 only)
UL
Approval under UL 1577, component recognition pro-
gram up to V
ISO
= 3750 V
RMS
. File E55361.
CSA
Approval under CSA Component Acceptance Notice #5,
File CA 88324.
OUTPUT POWER – P
S
, INPUT CURRENT – I
S
0
0
T
S
– CASE TEMPERATURE – C
200
600
400
25
800
50 75 100
200
150 175
P
S
(mW)
125
100
300
500
700
I
S
(mA)