PM100CVA120

Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Intellimod™ Module
Three Phase
IGBT Inverter Output
100 Amperes/1200 Volts
431
Description:
Powerex Intellimod™ Intelligent
Power Modules are isolated base
modules designed for power
switching applications operating
at frequencies to 20kHz. Built-in
control circuits provide optimum
gate drive and protection for the
IGBT and free-wheel diode
power devices.
Features:
Complete Output Power
Circuit
Gate Drive Circuit
Protection Logic
– Short Circuit
Over Temperature
Under Voltage
Applications:
Inverters
UPS
Motion/Servo Control
Power Supplies
Ordering Information:
Example: Select the complete
part number from the table below
-i.e. PM75CVA120 is a 1200V,
75 Ampere Intellimod™ Intelligent
Power Module.
Type Current Rating V
CES
Amperes Volts (x 10)
PM 100 120
Outline Drawing and Circuit Diagram
Dimensions Inches Millimeters
A 4.72 120.0
B 4.02 102.0
C 0.95+0.04/-0.02 24.1+1.0/-0.5
D 4.13±0.010 105.0±0.25
E 3.43±0.010 87.0±0.25
F 0.16 4.0
G 0.95 24.1
H 0.42 10.6
J 0.87 22.0
K 3.51±0.02 89.2±0.5
L 0.47 12.0
M 0.48 12.3
N 0.77 19.5
P 0.30 7.5
Dimensions Inches Millimeters
Q 0.59 15.1
R 0.72 18.25
S M5 Metric M5
T 0.22 Dia. Dia. 5.5
U 0.56±0.010 14.1±0.25
V 1.72±0.012 43.57±0.3
W 0.57±0.012 14.6±0.3
X 3.35 85.2
Y 0.85 21.6
Z 0.10±0.010 2.54±0.25
AA0.137±0.010 3.49±0.25
BB 0.02 SQ 0.64 SQ
CC
0.12+0.04/-0.02 3.0+1.0/-0.5
OUT
TEMP
Si
GND
VN1
WN
VNC
F
O
NC
NWVUP
Rf
O
V
CC
F
O
IN
TH
GND
OUT
Si
GND
VN
V
CC
F
O
IN
GND
OUT
Si
GND
UN
V
CC
F
O
IN
GND
OUT
Si
GND
V
WP1
W
P
W
FO
V
FO
U
FO
V
WPC
V
CC
F
O
IN
GND
OUT
Si
GND
V
VP1
V
P
V
VPC
V
CC
F
O
IN
GND
OUT
Si
GND
V
UP1
U
P
V
UPC
V
CC
F
O
IN
GND
Rf
O
= 1.5k OHM
TERMINAL CODE
1. W
FO
2. V
WPC
3. W
P
4. V
WP1
5. V
FO
6. V
VPC
7. V
P
8. V
VP1
9. U
FO
10. V
UPC
11. U
P
12. V
UP1
13. NC
14. F
O
15. VNC
16. VN1
17. UN
18. VN
19. WN
S NUTS (5 TYP.)
T (4 TYP.)
DP
A
B
K
E
1234
5678
9101112
13 14 1516
17 18 19
NP
UVW
J
TYP.
N
V
U
R
P
U
M
L - TYP.
M
Q
C
G
F
H
Y
XW
Z - TYP.
AA - TYP.
BB SQ PIN - TYP.
(19 PLACES)
CCØ
(4 PLACES)
DETAIL A
SEE
DETAIL A
PM100CVA120
PM100CVA120
Intellimod™ Module
Three Phase IGBT Inverter Output
100 Amperes/1200 Volts
432
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Absolute Maximum Ratings, T
j
= 25°C unless otherwise specified
Characteristics Symbol PM100CVA120 Units
Power Device Junction Temperature T
j
-20 to 150 °C
Storage Temperature T
stg
-40 to 125 °C
Case Operating Temperature T
C
-20 to 100 °C
Mounting Torque, M5 Mounting Screws (Typical) 17 in-lb
Mounting Torque, M5 Main Terminal Screws (Typical) 17 in-lb
Module Weight (Typical) 730 Grams
Supply Voltage (Applied between P - N) V
CC(surge)
1000 Volts
Supply Voltage Protected by SC (V
D
= 13.5 ~16.5V, Inverter Part, T
j
= 125°C Start) V
CC(prot.)
800 Volts
Isolation Voltage, AC 1 minute, 60Hz Sinusoidal V
RMS
2500 Volts
Control Sector
Supply Voltage Applied between (V
UP1
-V
UPC
, V
VP1
-V
VPC
, V
WP1
-V
WPC
, V
N1
-V
NC
)V
D
20 Volts
Input Voltage Applied between (U
P
, V
P
, W
P
, U
N
, V
N
, W
N
)V
CIN
20 Volts
Fault Output Supply Voltage (Applied between F
O
-GND) V
FO
20 Volts
Fault Output Current (Sink Current at F
O
Terminals) I
FO
20 mA
IGBT Inverter Sector
Collector-Emitter Voltage (V
D
= 15V, V
CIN
= 15V) V
CES
1200 Volts
Collector Current, ± (T
C
= 25°C) I
C
100 Amperes
Peak Collector Current, ± (T
C
= 25°C) I
CP
200 Amperes
Collector Dissipation (T
C
= 25°C) P
C
595 Watts
433
PM100CVA120
Intellimod™ Module
Three Phase IGBT Inverter Output
100 Amperes/1200 Volts
Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272
Electrical and Mechanical Characteristics, T
j
= 25°C unless otherwise specified
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Control Sector
Short Circuit Trip Level SC -20°C T
j
125°C, V
D
= 15V 145 Amperes
Short Circuit Current Delay Time t
off(SC)
V
D
= 15V 10 µS
Over Temperature Protection OT Trip Level 100 110 120 °C
(V
D
= 15V, Lower Arm) OT
r
Reset Level 85 95 105 °C
Supply Circuit Under Voltage Protection UV Trip Level 11.5 12.0 12.5 Volts
(-20°C T
j
125°C) UV
r
Reset Level 12.5 Volts
Circuit Current I
D
V
D
= 15V, V
CIN
= 15V, V
N1
-V
NC
—4055mA
V
D
= 15V, V
CIN
= 15V, V
XP1
-V
XPC
—1318mA
Input ON Threshold Voltage V
CIN(on)
Applied between U
P
-V
UPC
, V
P
-V
VPC
, 1.2 1.5 1.8 Volts
Input OFF Threshold Voltage V
CIN(off)
W
P
-V
WPC
, U
N
, V
N
, W
N
-V
NC
1.7 2.0 2.3 Volts
Fault Output Current I
FO(H)
V
D
= 15V, V
FO
= 15V* 0.01 mA
I
FO(L)
V
D
= 15V, V
FO
= 15V* 10 15 mA
Minimum Fault Output Pulse Width t
FO
V
D
= 15V* 1.0 1.8 mS
* Fault output is given only when the internal SC, OT, and UV protections circuits of either an upper-arm or a lower-arm device operate to protect it.

PM100CVA120

Mfr. #:
Manufacturer:
Description:
MOD IPM 6PAC 1200V 100A
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet