Part #:
Revision:
Weight (Typical)
Specifications:
Mode of Operation Continuous
2900 ± 500 Hz
6 to 28 VDC
Sound Level Category Loud
Voltage Rating
Frequency
-30° to +65° C
90 dB(A) @ 2 Feet and 28 Vdc
Current Draw 6-23mA
Housing Material
Storage Temperature
Operating Temperature
SC628N-BTR
B
Mallory Sonalert Products, Inc.
Sales Outline Drawing
Loudness @ 2 FT 86 to 97 dB(A) Typ.
-40° to +85° C
6/6 Nylon, Color: Black
Loudness @ Min Vdc 80 dB(A) @ 2 Feet and 6 Vdc
Loudness @ Max Vdc
cUL Recognized
Recommended hole size is 1.25"(31.75mm). Thread front will fit standard 30mm(1.181") hole.
4411 South High School Road, Indianapolis, Indiana 46241 U.S.A · Phone: (317) 612-1000 Fax: (317) 612-1010
www.mallory-sonalert.com
ROHS Compliant
Used to attach part to panel. The max recommended torque is 10 in-lbs.
1.6 oz (45g)
Approved with use of ACC03.
Please contact factory.
Inches (mm)
Dimensions:
NEMA 3R,4X, & 12
Options
Knurled Nut
Panel Mounting