AQV112KLAZ

–1–
ASCTB28E 201404-T
TYPES
*Indicate the DC values.
Note: The surface mount terminal shape indicator “A” and the packing style indicator “X” or “Z” are not marked on the device.
RATING
1. Absolute maximum ratings (Ambient temperature: 25°C 77°F)
Short circuit protection
(Non-latch type)
only for DC load
GU 1 Form A
Short Circuit Protection (AQV112KL)
Output rating*
Package
Part No.
Packing quantity
Through hole
terminal
Surface-mount terminal
Load
voltage
Load
current
Tube packing style
Tape and reel packing style
Tube Tape and reel
Picked from the
1/2/3-pin side
Picked from the
4/5/6-pin side
DC only 60 V 500 mA DIP6-pin AQV112KL AQV112KLA AQV112KLAX AQV112KLAZ
1 tube contains:
50 pcs.
1 batch contains:
500 pcs.
1,000 pcs.
Item Symbol AQV112KL(A) Remarks
Input
LED forward current I
F 50 mA
LED reverse voltage VR 5 V
Peak forward current IFP 1 A f = 100 Hz, Duty factor = 0.1%
Power dissipation Pin 75 mW
Output
Load voltage (peak AC) VL 7 to 60V
Continuous load current IL 0.5 A Peak AC, DC
Power dissipation Pout 500 mW
Total power dissipation PT 550 mW
I/O isolation voltage Viso 1,500 V AC
Temperature limits
Operating Topr –40°C to +85°C –40°F to +185°F Non-condensing at low temperatures
Storage Tstg –40°C to +100°C –40°F to +212°F
VDE
mm inch
FEATURES
1. Protects Circuit from excess current
The short circuit protection function
prevents the continued flow of short
current. After short current is detected,
load current is monitored, and if the load
returns to normal, the device returns to
normal operation.
2. No need for fuses, polyswitches, or
other protectors
The built-in short circuit protection
function eliminates the need for
overcurrent protectors, reducing
mounting costs and space requirements.
3. High capacity
Can control up to 0.5A (60V DC) load
current.
TYPICAL APPLICATIONS
• Industrial equipment
• Security equipment
6.4
3.9
8.8
.252
.154
.346
6.4
3.6
8.8
.252
.142
.346
1
2
3
6
5
4
RoHS compliant
GU 1 Form A Short Circuit Protection (AQV112KL)
–2–
ASCTB28E 201404-T
2. Electrical characteristics (Ambient temperature: 25°C 77°F)
*Turn on/Turn off time
RECOMMENDED OPERATING CONDITIONS
Please obey the following conditions to ensure proper device operation and resetting.
These products are not designed for automotive use.
If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation
technical representative.
REFERENCE DATA
Item Symbol AQV112KL(A) Condition
Input
LED operate current
Typical
IFon
0.8 mA
IL = 100mA
Maximum 10 mA
LED turn off current
Minimum
IFoff
0.3 mA
IL = 100mA
Typical 0.7 mA
LED dropout voltage
Typical
VF
1.35 V (1.17 V at IF = 10 mA)
IF = 50 mA
Maximum 1.5 V
Output
On resistance
Typical
Ron
0.55 Ω
I
F = 10 mA
I
L = Max.
Maximum 2.0 Ω
Load short circuit detection voltage
Typical
V
LSHT
5 V
IF = 10 mA
Maximum 7 V
Off state leakage current Maximum I
Leak 1μA
I
F = 0 mA
V
L = Max.
Transfer
characteristics
Turn on time*
Typical
T
on
2.0 ms
I
F = 10 mA
I
L = 100 mA
V
L = 10 V
Maximum 5.0 ms
Turn off time*
Typical
T
off
0.1 ms
I
F = 10 mA
I
L = 100 mA
V
L = 10 V
Maximum 1.0 ms
I/O capacitance
Typical
Ciso
0.8 pF
f = 1 MHz
V
B = 0 V
Maximum 1.5 pF
Initial I/O isolation resistance Minimum R
iso 1,000 MΩ 500 V DC
Item Symbol Recommended value Unit
Input LED current I
F 10 mA
Toff
Input
Output
Ton
90%
10%
1. Load current vs. ambient temperature
characteristics
Allowable ambient temperature: –40°C to +85°C
–40°F to +185°F
2. On resistance vs. ambient temperature
characteristics
Measured portion: between terminals 4 and 6;
LED current: 10 mA; Load current: Max.(DC)
3. Turn on time vs. ambient temperature
characteristics
Measured portion: between terminals 4 and 6;
LED current: 10 mA; Load voltage: 10V (DC);
Load current: 100 mA
0
100
200
300
400
500
600
0 2040608085100–40 –20
Ambient temperature, °C
Load current, mA
0
0.5
1
1.5
2
–40 –20 0 20 40 60 8085
Ambient temperature, °C
On resistance, Ω
0
2
3
–40 –20
5
020406080
1
4
85
Ambient temperature, °C
Turn on time, ms
GU 1 Form A Short Circuit Protection (AQV112KL)
–3–
ASCTB28E 201404-T
4. Turn off time vs. ambient temperature
characteristics
Measured portion: between terminals 4 and 6;
LED current: 10 mA; Load voltage: 10 V (DC);
Load current: 100 mA (DC)
5. LED operate current vs. ambient
temperature characteristics
Measured portion: between terminals 4 and 6;
Load current: 100 mA
6. LED turn off current vs. ambient temperature
characteristics
Measured portion: between terminals 4 and 6;
Load current: 100 mA
0
0.05
0.1
0.15
0.2
0.25
–40 –20
0.3
02040608085
Ambient temperature, °C
Turn off time, ms
0
0.5
1
1.5
2
2.5
–40 –20
3
02040608085
Ambient temperature, °C
LED operate current, mA
0
0.5
1
1.5
2
2.5
–40 –20
3
02040608085
Ambient temperature, °C
LED turn off current, mA
7. Off state leakage current vs. load voltage
characteristics
Measured portion: between terminals 4 and 6;
Ambient temperature: 25°C 77°F
8. Current vs. voltage characteristics of output
at MOS portion
Measured portion: between terminals 4 and 6;
Ambient temperature: 25°C 77°F
9. LED dropout voltage vs. ambient
temperature characteristics
Measured portion: between terminals 1 and 2;
LED current: 10 to 50 mA
20 30 40 50 60100
10
-12
10
-11
10
-10
10
-9
10
-8
10
-7
10
-6
Load voltage, V
Off state leakage current, A
–0.6
–0.4
–0.2
0
0.2
0.4
0.6
–1 –0.5 0 0.5 1
Voltage, V
Current, A
1
1.2
1.3
–40 –20
1.5
020406080
1.1
1.4
85
Ambient temperature, °C
LED dropout voltage, V
50mA
30mA
20mA
10mA
10. Turn on time vs. LED forward current
characteristics
Measured portion: between terminals 4 and 6;
Load voltage: 10 V (DC); Load current: 100 mA (DC);
Ambient temperature: 25°C 77°F
11. Turn off time vs. LED forward current
characteristics
Measured portion: between terminals 4 and 6;
Load voltage: 10 V (DC); Load current: 100 mA (DC);
Ambient temperature: 25°C 77°F
12. Output capacitance vs. applied voltage
characteristics
Measured portion: between terminals 4 and 6;
Frequency: 1 MHz; Ambient temperature: 25°C 77°F
–1
4
3
2
1
0
5
0 1020304050
LED forward current, mA
Turn on time, ms
0
0.05
0.1
0.15
0.2
0 1020304050
LED forward current, mA
Turn off time, ms
0
100
200
300
400
500
0 102030405060
Applied voltage, V
Output capacitance, pF
13. Short circuit peak current vs. time
characteristics
Measured portion: between terminals 4 and 6;
LED current: 10 mA; Load resistance: 0Ω;
Ambient temperature: 25°C 77°F
14. Short current monitoring interval vs. time
characteristics
Measured portion: between terminals 4 and 6;
LED current: 10 mA; Load resistance: 0Ω;
Ambient temperature: 25°C 77°F
1
1.5
2
V
L=12V
V
L=24V
V
L=60V
2.5
3
4
3.5
0 102030405060
Time, S
Short circuit peak current, A
VL=12V
V
L=24V
V
L=60V
0
5
10
15
20
30
25
0 102030405060
Time, S
Short current monitoring interval, ms

AQV112KLAZ

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
Solid State Relays - PCB Mount 60v 500mA DIP Form A Norm-Open
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet