KRP-14DG-12

737
P&B
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
PDF Revised 9-03
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Initial Dielectric Strength
Between Open Contacts: 500V rms.
Between All Elements: 1,500V rms.
Features
Industry standard octal-type termination for quick installation.
Contact arrangements from 1 Form C (SPDT) to 3 Form C (3PDT).
Indicator lamp and push-to-test options available on certain models.
The KRPA is the automated manufactured version of the KRP.
Mechanical Data
Termination: Open Models: Solder terminals.
Enclosed Models: Octal-type plug.
Enclosure: Transparent polycarbonate.
Weight: KA: 1.7 oz. (48.2g) approximately.
KRPA, KRP: 3.0 oz. (85g) approximately.
Environmental Data
Temperature Range:
Open Models: AC: -45°C to +70°C.
DC: -45°C to +85°C.
Enclosed Models: AC: -45°C to +55°C.
DC: -45°C to +70°C.
Operate Data @ 25°C
Must-Operate Voltage:
DC: 75% or less of nominal voltage.
AC: 85% or less of nominal voltage.
Operate Time (Excluding Bounce):
15 milliseconds typical @ nominal voltage.
Release Time (Excluding Bounce):
10 milliseconds typical @ nominal voltage.
KRPA, KRP, KA, KR
series
5 to 10 Amp
General Purpose Relay
File E29244, E22575
File LR15734
Users should thoroughly review the technical data before selecting a product
part number. It is recommended that users also seek out the pertinent approvals
files of the agencies/laboratories and review them to ensure the product meets
the requirements for a given application.
Contact Data @ 25°C
Arrangements: See Ordering Information Table.
Materials: Silver or silver-cadmium oxide, with or without gold flashing.
Expected Life: 10 million operations min., mechanical; 100,000
operations min. @ rated loads.
KRPKRPA
KA
Coil Data @ 25°C
Nominal DC Resistance () Nominal Coil
Voltage ±10% Current (mA)
632 188
12 120 100
DC 24 472 51
Coils 48 1,800 26.6
110 10,0 00 11.5
220
Use 110V relay with 10,000 5W Resistor in series
6 6 335
AC 12 24 168
Coils 24 85 84
120 2,250 17.5
240 9,110 8.75
Note: See KRPA, KRP, KA Ordering Information table.
KA, KRP, KRPA UL/CSA Contact Ratings @ 25°C
Contact Code Arrangement Contact Rating
Y 1, 2, 3 Poles 5A @ 120VAC
(Silver) 3A @ 240VAC
1/10HP @ 120VAC
1/6HP @ 240VAC
G&N 1, 2, 3 Poles 10A @ 240VAC
(Silver-Cad. 1/2 HP @ 240VAC
Oxide) 1/3HP @ 120VAC
KRP, KRPA Factory Ratings
Contact Code Arrangement Contact Rating
Y 1, 2, 3 Poles 5A @ 28VDC, 120VAC, 80% PF
G&N 1, 2, 3 Poles 10A @ 28VDC, 120VAC, 80% PF
6A @ 250VAC
KA UL Contact Ratings
Contact Code Series Contact Ratings
YKA
1
5A @ 120VAC, 3A @ 240VAC,
1/10 HP @ 120VAC, 1/6 HP @ 240VAC
GKA
2
10A @ 120VAC, 6A @ 240VAC
1/6 HP @ 120VAC, 1/3 HP @ 240VAC
1
Listed by C.S.A. for 5A @ 120VAC 80% PF
2
Listed by C.S.A. for 10A @ 120VAC 80% PF
Coil Data @ 25°C
Nominal Power Maximum Power
KRP AC 2VA Enclosed Models - 4VA
KRPA DC 1.2W Enclosed Models - 3W
KA AC 2VA Open Models - 4VA
DC 125mW per movable arm Open Models - 4W
Duty Cycle: Continuous.
Initial Insulation Resistance: KRP, KRPA - 1000 Megohms, min.
KA - 100 Megohms, min.
738
P&B
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
PDF Revised 9-03
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Our authorized distributors are more likely to stock the following items for immediate delivery.
KA-5AG-120
KA-5AY-120
KA-5DG-6
KA-5DG-12
KA-5DG-110
KA-11AG-120
KA-11AY-6
KA-11AY-24
KA-11AY-120
KA-11DG-12
KA-11DG-24
KA-11DG-110
KA-14AG-120
KA-14AY-120
KA-14DG-24
KA-14DG-110
KRP-5AG-120
KRP-11AG-24
KRP-11AG-120
KRP-11AG-240
KRP-11AN-24
KRP-11AN-120
KRP-11AY-120
KRP-11DG-12
KRP-11DG-24
KRP-11DG-48
KRP-11DG-110
KRP-11DG-125
KRP-11DN-12
KRP-11DN-24
KRP-11DY-24
KRP-14AG-120
KRP-14AG-240
KRP-14AN-120
KRP-14AY-120
KRP-14DG-12
KRP-14DG-24
KRP-14DG-110
KRP-14DN-24
KRPA-5AG-24
KRPA-5AG-120
KRPA-5AY-120
KRPA-5DG-6
KRPA-5DG-12
KRPA-5DG-24
KRPA-5DY-12
KRPA-5DY-24
KRPA-11AG-6
KRPA-11AG-12
KRPA-11AG-24
KRPA-11AG-120
KRPA-11AG-240
KRPA-11AN-12
KRPA-11AN-24
KRPA-11AN-120
KRPA-11AN-240
KRPA-11AY-6
KRPA-11AY-12
KRPA-11AY-24
KRPA-11AY-120
KRPA-11AY-240
KRPA-11DG-6
KRPA-11DG-12
KRPA-11DG-24
KRPA-11DG-48
KRPA-11DG-110
KRPA-11DN-12
KRPA-11DN-24
KRPA-11DN-110
KRPA-11DY-12
KRPA-11DY-24
KRPA-14AG-12
KRPA-14AG-24
KRPA-14AG-120
KRPA-14AG-240
KRPA-14AN-24
KRPA-14AN-120
KRPA-14AN-240
KRPA-14AY-24
KRPA-14AY-120
KRPA-14AY-240
KRPA-14DG-12
KRPA-14DG-24
KRPA-14DG-48
KRPA-14DG-110
KRPA-14DN-24
KRPA-14DY-24
Ordering Information
Typical Part No. B KRPA -5 A Y -120
1. Series:
KRPA (Newer version, enclosed)
KRP (Older version, enclosed)
KA (Open style)
2. Contact Arrangement:
5 = 1 Form C (SPDT) 11 = 2 Form C (DPDT) 14 = 3 Form C (3PDT)
3. Coil Input:
A = AC, 50/60 Hz.
D = DC
4. Contact Rating and Indicator Lamp Option:
TYPE KRPA KRP KA
Codes
Y, G, N, Y, G, N, Y, G,
Available
Y = Silver, no indicator lamp
G = Silver-cadmium oxide, no indicator lamp
N = Silver-cadmium oxide, with indicator lamp*
5. Coil Voltage:
Up to 240VAC
Up to 125VDC
*
Indicator Lamp not available on 25-90V coils. Only 120-240VAC and 110VDC models are UL recognized and CSA certified.
739
P&B
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
PDF Revised 9-03
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Coil Data @ 25°C
See chart on page 105.
Nominal Power: DC Coils: 1.2W
AC Coils: 2.0VA
Initial Insulation Resistance: 1,000 megohms.
Environmental Data
Temperature Range: Enclosed Models: AC: -45°C to +55°C.
DC: -45°C to +70°C.
Operate Data @ 25°C
Must-Operate Voltage: DC: 75% of nominal voltage.
AC: 85% of nominal voltage.
Operate Time: 15 milliseconds approximate (Excluding Bounce).
Release Time: 10 milliseconds approximate (Excluding Bounce).
Mechanical Data
Mounting: Socket mounting.
Termination: Octal-type plug.
Enclosure: Polycarbonate enclosure with octal-type mounting.
Weight: 2 oz. (57g) approximately.
Initial Dielectric Strength
Between Open Contacts: 500V rms, 60 Hz. between all elements.
Features
• 1 Form X (SPST - NO - DM) contact rating of 20A.
• Heavy copper alloy movable contact arms.
• Twin silver-cadmium oxide contacts.
• Many uses in automation controls and other applications requiring high
current switching.
KRP-3-H
series
20 Amp
Small AC or DC Relays
File E22575
Contact Data @ 25°C
Arrangement: 1 Form X (SPST - NO - DM).
Ratings: UL Rating: 20A @ 120VAC, 3/4 HP @ 120VAC.
Factory Rating: 20A @ 120VAC, 80% PF; 1 HP @
120/240VAC.
Material: Twin, silver-cadmium oxide.
Expected Life: 2.5 million operations min., mechanical. 100,000
operations at rated contact load.
KRP-3-H
Our authorized distributors are more likely to stock the following items for immediate delivery.
Ordering Information
KRP-3AH-120
KRP-3DH-24
KRP-5AG-120
Typical Part No. B KR P -3 D H -12
1. Basic Series: KR
2. Type:
P = Enclosed
(20 amp models available only with Contact Arrangement 3 and Material H.)
3. Contact Arrangement:
3 = 1 Form X (SPST - NO - DM)
4. Coil Input:
A = AC
D = DC
5. Contact Material & Rating:
H = Silver-cadmium oxide, 1/4" (6.35mm) dia., 20 amps.
6. Coil Voltage:
To 240VAC, 50/60 Hz. or 110VDC.

KRP-14DG-12

Mfr. #:
Manufacturer:
TE Connectivity / Potter & Brumfield
Description:
General Purpose Relays 3PDT 10A 12VDC GEN PURPOSE RELAY
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union