Absolute Maximum Ratings Thermal Information
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Voltage on SCK, any Address Input,
with Respect to VSS. . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
V = |(VH - VL)| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5V
I
W
(10 seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6mA
Supply Voltage (V
CC
) Limits:
X9271 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V ± 10%
X9271-2.7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
Recommended Operating Conditions
Temperature Range (Commercial). . . . . . . . . . . . . . . . 0°C to +70°C
Temperature Range (Industrial) . . . . . . . . . . . . . . . . -40°C to +85°C
Maximum Storage Temperature Range . . . . . . . . . .-65°C to +150°C
Maximum Lead Temperature (Soldering 10s) . . . . . . . . . . . . +300°C
Pb-Free Reflow Profile. . . . . . . . . . . . . . . . . . . . . . . . . . . see TB493
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and
result in failures not covered by warranty.
Analog Characteristics Across recommended industrial operating conditions unless otherwise specified.
SYMBOL PARAMETER
LIMITS
TEST CONDITIONS
MIN
(Note 17
)TYP
MAX
(Note 17)UNITS
R
TOTAL
End to End Resistance 50 kΩ U version
End to End Resistance
Toler an ce
±20 %
Power Rating 50 mW +25°C, each pot
I
W
Wiper Current ±3 mA
R
W
Wiper Resistance 300 WI
W
= ± 3mA at V
CC
= 3V
R
W
Wiper Resistance 150 WI
W
= ± 3mA at V
CC
= 5V
V
TERM
Voltage on any R
H
or R
L
Pin V
SS
V
CC
VV
SS
= 0V
Noise -120 dBVHz
Ref: 1V
Resolution
0.4 %
Absolute Linearity (Note 10
) ±1 MI
(Note 12
)
R
w(n)(actual) -
R
w(n)(expected)
(Note 14)
Relative Linearity (Note 11
) ±0.2 MI
(Note 12
)
R
w(n + 1)
- [R
w(n) + MI
] (Note 14)
Temperature Coefficient of
R
TOTAL
±300 ppm/C
Ratiometric Temp.
Coefficient
20 ppm/°C
C
H
/C
L
/C
W
Potentiometer
Capacitance
10/10/25 pF See macro model
NOTES:
10. Absolute linearity is used to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
11. Relative linearity is used to determine actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
12. MI = RTOT / 255 or (R
H
- R
L
) / 255, single pot.
13. During power-up, V