DC and AC characteristics M27C801
14/24
Figure 6. AC testing load circuit
Table 6. Capacitance
(1)
(2)
1. T
A
= 25 °C, f = 1 MHz.
2. Sampled only, not 100% tested.
Symbol Parameter Test condition Min. Max. Unit
C
IN
Input capacitance V
IN
= 0 V 6 pF
C
OUT
Output capacitance V
OUT
= 0 V 12 pF
Table 7. Read mode DC characteristics
(1)
(2)
1. T
A
= 0 to 70 °C or –40 to 85 °C; V
CC
= 5 V ± 10%.
2. V
CC
must be applied simultaneously with or before V
PP
and removed simultaneously or after V
PP
.
Symbol Parameter Test condition Min. Max. Unit
I
LI
Input leakage current 0V ≤ V
IN
≤ V
CC
±10 µA
I
LO
Output leakage current 0V ≤ V
OUT
≤ V
CC
±10 µA
I
CC
Supply current
E
= V
IL
, GV
PP
= V
IL
,
I
OUT
= 0mA, f = 5MHz
35 mA
I
CC1
Supply current (Standby) TTL E = V
IH
1mA
I
CC2
Supply current (Standby)
CMOS
E
> V
CC
– 0.2V 100 µA
I
PP
Program current V
PP
= V
CC
10 µA
V
IL
Input low voltage –0.3 0.8 V
V
IH
(3)
3. Maximum DC voltage on Output is V
CC
+0.5V.
Input high voltage 2 V
CC
+ 1 V
V
OL
Output low voltage I
OL
= 2.1 mA 0.4 V
V
OH
Output high voltage TTL I
OH
= –1 mA 3.6 V
Output high voltage CMOS I
OH
= –100 µA V
CC
– 0.7 V
AI01823B
1.3V
OUT
C
L
C
L
= 30pF for High Speed
C
L
= 100pF for Standard
C
L
includes JIG capacitance
3.3kΩ
1N914
DEVICE
UNDER
TEST
Obsolete Product(s) - Obsolete Product(s)