PLC-30-48

THD< 20% when output loading 70% at 115VAC/230VAC input
TOTAL HARMONIC DISTORTION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC
SPECIFICATION
MODEL PLC-30-9 PLC-30-15PLC-30-12 PLC-30-20 PLC-30-24 PLC-30-27 PLC-30-36 PLC-30-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
SHORT CIRCUIT
OVER VOLTAGE
OVER TEMPERATURE
9V 15V
10.5 ~ 15V
12V
8.4 ~ 12V
20V
14 ~ 20V
24V
16.8 ~ 24V
27V
18.9 ~ 27V
36V
25.2 ~ 36V
48V
33.6 ~ 48V
3.3A 2A2.5A 1.5A 1.25A 1.12A 0.84A 0.63A
0 ~ 3.3A 0 ~ 2A0 ~ 2.5A 0 ~ 1.5A 0 ~ 1.25A 0 ~ 1.12A 0 ~ 0.84A 0 ~ 0.63A
29.7W 30W30W 30W 30W 30.24W 30.24W 30.24W
2.6Vp-p 2.6Vp-p2Vp-p 2.6Vp-p 2.4Vp-p 2.3Vp-p 3.6Vp-p 3.7Vp-p
±3.0%
±10%
±5.0%
500ms / 230VAC 3000ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
PF>0.95/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
80% 83.5%82.5% 84% 84% 84.5% 85% 85.5%
10 ~ 14V 17 ~ 22V14 ~ 17V 23 ~ 26V 27 ~ 34V 31 ~ 35V 40 ~ 50V 53 ~ 63V
0.4A/115VAC 0.2A/230VAC
COLD START 35A(twidth=25 s measured at 50% Ipeak) at 230VACμ
<0.5mA / 240VAC
100 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
-30 ~ +50 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.06%/ (0 ~ 50 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
625.5Khrs min. MIL-HDBK-217F (25 )
160*46*30mm (L*W*H)
0.2Kg; 70pcs/15Kg/0.96CUFT
Protection type : Shut down o/p voltage, re-power on to recover
30W Single Output LED Power Supply
Universal AC input / Full range
Adjustable output voltage and current level
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
Fully isolated plastic case with terminal block style of I/O
Built-in active PFC function, comply with EN61000-3-2 class C
(Pin 25W)
Class power unit, no FG
Class 2 power unit
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications (Note.2)
Compliance to worldwide safety regulations for lighting
2 years warranty
Features :
PLC-30 series
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
6.3 ~ 9V
CONSTANT CURRENT REGION
Note.6
Compliance to EN55015, EN61000-3-2 Class C (Pin 25W), Class D (>70% load) ; EN61000-3-3GB17743, GB17625.1,
,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level, criteria A,EAC TP TC 020
VOLTAGE ADJ. RANGE Note.5
CURRENT ADJ. RANGE
Note.5
11.4 ~ 13.2V8.55 ~ 9.9V
1.875 ~ 2.575A
2.475 ~ 3.399A
14.5 ~ 16.5V
1.5 ~ 2.06A
19 ~ 22V 22.8 ~ 26.4V
0.938 ~ 1.288A
25.65 ~ 29.7V
0.84 ~ 1.1536A
34.2 ~ 39.6V
0.63 ~ 0.865A
45.6 ~ 52.8V
0.473 ~ 0.649A
1.125 ~ 1.545A
..
M M
110
SELV
EMC IMMUNITY
EMC EMISSION
UL1310, TUV EN61347-1, EN61347-2-13, , CAN/CSA C22.2 No. 223-M91(except for 48V), J61347-1, J61347-2-13 approved
GB19510.14,GB19510.1
,EAC TP TC 004
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6. Please refer to "DRIVING METHODS OF LED MODULE".
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
10. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
File Name:PLC-30-SPEC 2018-01-11
S
&
E
( for 48V only) ( except for 48V )
Mechanical Specification
File Name:PLC-30-SPEC 2018-01-11
Case No. 990A Unit:mm
3.2
9
160
3.2
2.3
30
46
9
2-R22-R2
2-R6.5
Vo
ADJ
Io
ADJ
Terminal Pin No. Assignment (TB1) :
SWITCHLAB MB310-75002
Terminal Pin No. Assignment (TB2) :
SWITCHLAB MB310-75002
Pin No. Pin No.
11
1
1
2
2
22
Assignment Assignment
AC/L -V
AC/N +V
Static Characteristics
T case: Max. Case Temperature.
80
Tcase
23
30W Single Output LED Power Supply
PLC-30 series
fosc : 39KHz(115VAC)
53KHz(230VAC)
LOAD (%)
-25 -5 0 15 30
20
40
60
80
100
LOAD (%)
-25 -5 0 15 30 40 50
20
40
60
80
100
Block Diagram
DETECTION
PWM & PFC
CIRCUIT
O.L.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
CONTROL
O.V.P.
&
O.C.P.
AMBIENT TEMPERATURE ( )
LOAD (%)
-30 60
Derating CurveDerating Curve
INPUT VOLTAGE (V) 60Hz
90 100 125 135 145 155 165 175 180 200 230 264
100
90
80
70
60
50
40
LOAD (%)
54
56
58
60
62
64
66
68
70
72
74
76
78
80
82
84
86
88
90
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
230V
115V
0.78
0.80
0.82
0.84
0.86
0.88
0.90
0.92
0.94
0.96
0.98
1.00
50% 60% 70% 80% 90% 100%
230V
115V
Power Factor Characteristic
EFFICIENCY vs LOAD (48V Model)
PLC-30 series possess superior working efficiency that up to 85.5% can be reached in field applications.
Constant Current Mode
PF
LOAD
EFFICIENCY (%)
LOAD
DRIVING METHODS OF LED MODULE
(30W)
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
File Name:PLC-30-SPEC 2018-01-11
30W Single Output LED Power Supply
PLC-30 series
Typical LED power supply I-V curve
Vo(%)
100
70
50 100
(min.)
Io (%)
Constant
Current area
Hiccup
Protection
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.

PLC-30-48

Mfr. #:
Manufacturer:
MEAN WELL
Description:
LED Power Supplies 30.24W 48V 0.63A LED Power Supply
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union