HWD075DGE-A2H9

REV. JUN 27, 2003
Page 1 of 12
HWD DC/DC Series Data Sheet
Applications
Distributed power architectures
Telecommunications equipment
LAN/WAN applications
Data processing applications
Features
75 Watts total output power
Wide input range 18V – 60V
Independent dual outputs
Flexible load sharing
Open-frame design with IMS board
Low profile – 12.7mm height
Start-up into high capacitive load
Output overcurrent protection (self restart)
Output overvoltage protection (self restart)
Overtemperature protection (self restart)
Setpoint accuracy ± 2.0%
Output voltage trim adjust, independent for
each output
Input/output isolation: 1500V
UL 1950 Recognition, CSA 22.2 No. 950-95
certification
Description
The HWD series provides onboard conversion of standard telecom and datacom input voltages into two isolated
low-voltage outputs. These products offer a unique combination of wide input range, low profile, and high current
capability. High efficiency and advanced thermal management enable these half-brick products to deliver full rated
power at 55°C ambient temperature, with 200 LFM airflow, without the addition of heatsinks.
Model Selection
Model Input
Voltage
Range, VDC
Input
Current,
Max, ADC
Output
Voltage,
VDC
Output Rated
Current, ADC
Output Ripple
and Noise,
mV p-p
Efficiency %
HWD075DGE-A 18-60 5.5 5.0/3.3 15/15 100 81% @ 24Vin
79% @ 48Vin
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not authorized for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional
president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
HWD DC/DC Series Data Sheet
REV. JUN 27, 2003
Page 2 of 12
HWD DC/DC Series Data Sheet
Table 1. Absolute Maximum Ratings
Parameter Symbol Min Max Units
Input Voltage
Continuous
Transient (100 msec)
Vi
Vi
-
-
60
100
VDC
VDC
Operating Baseplate Temperature
Note 1
Tb -40 +100
°C
Storage Temperature Tstg -55 +125
°C
Input to Output Isolation - - 1500 VDC
Output Short Circuit Duration - - Continuous -
Total Output Power P
o
max - 75 W
No Load Power Dissipation - 6 W
Electrical Specifications
Unless otherwise indicated, specifications apply over all input voltages, resistive load, and Tbp=+40°C.
Table 2. Input Specifications
Parameter Symbol Min Typ Max Units
Voltage Range Vi 18* 24/48 60 VDC
Maximum Input Current Ii - - 5.5 A
Input Ripple Rejection (120 Hz) - 60 - dB
Inrush Transient - - 1 A
2
s
Input Reflected Ripple (see figure 1) - - 250 mA p-p
Module will operate within specification with an input voltage of 18 VDC, but must be turned on with an input voltage > 19.5 VDC.
See Undervoltage Lockout Specification.
Fusing Considerations
CAUTION
This DC-DC converter is not internally fused. An external input fuse must always be used.
REV. JUN 27, 2003
Page 3 of 12
HWD DC/DC Series Data Sheet
Table 3. Output Specifications
Parameter Symbol Min Typ Max Units
Output Power
Po1
Po2
Po1+Po2
-
-
-
-
-
-
75
50
75
W
W
W
Output Voltage Set Point
(Vi=24VDC or Vi=48VDC,
Io1,Io2=7.5A)
Vo1
Vo2
4.9
3.23
5.0
3.3
5.1
3.37
VDC
VDC
Output Line Regulation:
(Vi=Vi,min to Vi,max)
(Io1, Io2=7.5A)
Vo1,Vo2
- 0.05 0.2 %
Output Load Regulation:
(Io,min to Io,max)
Vo1,Vo2
- 0.5 1 %
Output Temperature Regulation:
(Tbase =-40°C to +100°C)
All Outputs - 0.02 0.05
%/°C
Output Current
(Maximum output power limited to
75W)
Io1
Io2
0.5
0.5
7.5
7.5
15
15
A
A
Output Ripple (See Figure 2)
(DC to 20MHz)
(Io1,Io2 = 7.5A)
Vo1
Vo2
-
-
75
75
100
100
mVp-p
mVp-p
Output Current Limit inception
(Other outputs at no load)
Io1
Io2
-
-
17
21
19
23
A
A
Transient Response
(50% to 100% Load Step,
Io/t=0.1A/uSec)
Peak Deviation
Settling Time (Vo, 1% of Vo1)
Vo1
Vo2
-
-
-
100
200
150
200
300
250
mV
mV
µsec
Overvoltage Limit Vo1,clamp
Vo2,clamp
5.9
3.6
-
-
6.5
4.7
VDC
VDC
Table 4. Feature Specifications
Parameter Symbol Min Typ Max Units
Remote On/Off, Primary side
Vlow
Vhigh
Sink Current-Logic Low
-
-
-
-
-
-
1
7
2
V
V
mA
Turn-on time (Within 1% V
o
nom) - 3.5 5 msec
Switching Frequency - 350 - kHz
Output Voltage Adjust
Adjust Up
Adjust Down
Vo1
Vo2
Vo1
Vo2
5.39
3.55
4.41
2.91
5.5
3.63
4.5
2.97
5.61
3.71
4.59
3.03
VDC
VDC
VDC
VDC
Thermal Shutdown +105 +115
°C
Undervoltage Lockout
Turn-on
Turn-off
-
16.5
19.2
16.8
19.5
-
V
V

HWD075DGE-A2H9

Mfr. #:
Manufacturer:
Bel
Description:
DC DC CONVERTER 5V 3.3V 75W
Lifecycle: