NL17SG14
www.onsemi.com
4
AC ELECTRICAL CHARACTERISTICS (Input t
r
= t
f
= 3.0 ns)
Symbol Parameter Test Condition V
CC
(V)
T
A
= 25 5C
T
A
=
−555C to +1255C
Unit
Min Typ Max Min Max
t
PLH
,
t
PHL
Propagation Delay,
A or Y
C
L
= 10 pF,
R
L
= 1 MW
0.9 − 27.3 − − −
ns
1.1 to 1.3 − 13.0 22.6 1.0 35.9
1.4 to 1.6 − 7.5 10.5 1.0 11.3
1.65 to 1.95 − 6.0 7.8 1.0 8.2
2.3 to 2.7 − 4.3 5.4 1.0 5.8
3.0 to 3.6 − 3.5 4.4 1.0 4.6
C
L
= 15 pF,
R
L
= 1 MW
0.9 − 29.5 − − −
ns
1.1 to 1.3 − 14.3 25.1 1.0 41.6
1.4 to 1.6 − 8.0 11.5 1.0 12.6
1.65 to 1.95 − 6.3 8.4 1.0 8.7
2.3 to 2.7 − 4.6 5.7 1.0 6.1
3.0 to 3.6 − 3.7 4.6 1.0 5.0
C
L
= 30 pF,
R
L
= 1 MW
0.9 − 40.5 − − −
ns
1.1 to 1.3 − 19.6 35.7 1.0 58.1
1.4 to 1.6 − 10.7 15.8 1.0 17.6
1.65 to 1.95 − 7.8 10.7 1.0 11.7
2.3 to 2.7 − 5.4 6.9 1.0 8.1
3.0 to 3.6 − 4.3 5.2 1.0 6.1
C
IN
Input Capacitance 0 to 3.6 3 − − − pF
C
O
Output Capacitance V
O
= GND 0 3 − − − pF
C
PD
Power Dissipation
Capacitance (Note 5)
f = 10 MHz 0.9 to 3.6 − 4 − − − pF
Product parametric performance is indicated in the Electrical Characteristics for the listed test conditions, unless otherwise noted. Product
performance may not be indicated by the Electrical Characteristics if operated under different conditions.
5. C
PD
is defined as the value of the internal equivalent capacitance which is calculated from the dynamic operating current consumption without
load. Average operating current can be obtained by the equation: I
CC(OPR
)
= C
PD
V
CC
f
in
+ I
CC
. C
PD
is used to determine the no−load
dynamic power consumption; P
D
= C
PD
V
CC
2
f
in
+ I
CC
V
CC
.