MAX695MJE/883B

TEST Symbol
CONDITIONS
-55 °C T
A
+125°C 2/
Unless otherwise specified
Group A
Subgroup
Device
type
Limits
Min
Limits
Max
Units
POWER-FAIL DETECTOR
PFI Input
Threshold
PFI
VTH
V
CC
=5V 1,2,3 All 1.2 1.4 V
PFI Input Current PFII
IN
1,2,3 All -25 25 nA
___
PFO Output
Voltage High
___
PFO
VOH
I
SOURCE
=1µA, V
CC
=5V
1,2,3 All 3.5 V
___
PFO Output
Voltage Low
___
PFO
VOL
I
SINK
=3.2mA
I
SINK
=1.6mA
1
2,3
All
0.4
0.4
V
___
PFO Short-Circuit
Source Current
___
PFO
IOS
___
PFI=V
IH
, PFO=0V 1,2,3 All 1.0 25
µA
CHIP-ENABLE GATING
__
CE IN Thresholds
Logic Low
__
CEV
IL
1
2,3
02,04,06
0.8
0.4
V
__
CE IN Thresholds
Logic High
__
CEV
IH
1
2,3
02,04,06
3.0
4.0
V
__
CE IN Pull-Up
Current
__
CE IN
PI
1,2,3 02,04,06 1.0 25
µA
__
CE OUT Output
Voltage High
__
CE
VOH
I
SOURCE
=3.0mA,
V
CC
=4.75V
I
SOURCE
=1µA, V
CC
=0V
1,2,3 02,04,06
V
OUT
-1.5
V
OUT
-0.05
V
__
CE Output Voltage
Low
__
CE
VOL
I
SINK
=3.2mA
I
SINK
=1.6mA
1
2,3
02,04,06
0.4
0.4
V
__
CE Propagation
Delay
___
t
PDCE
V
CC
=5V
9
10,11
02,04,06
200
300
ns
OSCILLATOR
OSC IN Input
Current Pull-Up
OSCI
IN
1,2,3 02,04,06 25
µA
OSC SEL Input
Pull-Up Current
OSC
SEL
IN
1,2,3 02,04,06 1 25
µA
OSC IN Frequency
Range
OSC
INfrq
OSC SEL=0V 9,10,11 02,04,06 0 250 kHz
OSC IN Frequency
with External
Capacitor
OSC
IN
OSC SEL=0V, COSC=47pF
NOTE 4
9 02,04,06 4 kHz
NOTE 2: V
CC
=full operating range, V
BATT
=+2.8V.
NOTE 3: WDI is guaranteed to be in the mid-level (inactive) state if WDI is floating and V
CC
is in the operating
range. WDI is internally biased to 38% of V
CC
with an impedance of approximately 125k
NOTE 4: Typical for design purposes only but not tested. Guaranteed for SMD 5962-90711 and 5962-90712.
---------------------------- Electrical Characteristics of MAX690/691/692/693/694 19-2553 Rev. C
/695/883B for /883B and SMD 5962-90711 and 5962-90712 Page 5 of 8
Package ORDERING INFORMATION: SMD NUMBER
01 8 pin CERDIP MAX690MJA/883B 5962-9071201MPA
01 10 pin Flatpack MAX690MFB/883B 5962-9071201MXC
01 20 pin LCC MAX690MLP/883B 5962-9071201M2C
02 8 pin CERDIP MAX691MJA/883B 5962-9071101MPA
02 20 pin LCC MAX691MLP/883B 5962-9071101M2C
03 8 pin CERDIP MAX692MJA/883B 5962-9071202MPA
03 10 pin Flatpack MAX692MFB/883B 5962-9071202MXC
03 20 pin LCC MAX692MLP/883B 5962-9071202M2C
04 8 pin CERDIP MAX693MJA/883B 5962-9071102MPA
04 20 pin LCC MAX693MLP/883B 5962-9071102M2C
05 8 pin CERDIP MAX694MJA/883B 5962-9071203MPA
05 10 pin Flatpack MAX694MFB/883B 5962-9071203MXC
05 20 pin LCC MAX694MLP/883B 5962-9071203M2C
06 8 pin CERDIP MAX695MJA/883B 5962-9071103MPA
TERMINAL CONNECTIONS:
MAX690/692/694 MAX690/692/694 MAX690/692/694 MAX691/693/695 MAX691/693
J8 F10 L20 J16 L20
1V
OUT
V
OUT
NC V
BATT
NC
2V
CC
V
CC
V
BATT
V
OUT
V
BATT
3 GND GND V
OUT
V
CC
V
OUT
4PFI NC V
CC
GND V
CC
5 ____
PFO
PFI GND BATT ON GND
6 WDI ____
PFO
NC _________
LOWLINE
NC
7 ______
RESET
WDI NC
OSC IN
BATT ON
8V
BATT
NC NC OSC SEL _________
LOWLINE
9 ______
RESET
NC PFI
OSC IN
10 V
BATT
NC ____
PFO
OSC SEL
11 NC WDI NC
12 PFI __
CE OUT
PFI
13 ____
PFO
__
CE IN
____
PFO
14 WDI ____
WDO
WDI
15 NC ______
RESET
__
CE OUT
16 NC RESET NC
17 NC __
CE IN
18 NC ____
WDO
19 ______
RESET
______
RESET
20 NC RESET
---------------------- Electrical Characteristics of MAX690/691/692/693/694 19-2553 Rev. C
------ /695/883B for /883B and SMD 5962-90711 and 5962-90712 Page 6 of 8
QUALITY ASSURANCE
Sampling and inspection procedures shall be in accordance with MIL-Prf-38535, Appendix A as specified in Mil-
Std-883.
Screening shall be in accordance with Method 5004 of Mil-Std-883. Burn-in test Method 1015:
1. Test Condition, A, B, C, or D.
2. TA = +125°C minimum.
3. Interim and final electrical test requirements shall be specified in Table 2.
Quality conformance inspection shall be in accordance with Method 5005 of Mil-Std-883, including Groups A, B,
C, and D inspection.
Group A inspection:
1. Tests as specified in Table 2.
2. Selected subgroups in Table 1, Method 5005 of Mil-Std-883 shall be omitted.
Group C and D inspections:
a. End-point electrical parameters shall be specified in Table 1.
b. Steady-state life test, Method 1005 of Mil-Std-883:
1. Test condition A, B, C, D.
2. TA = +125°C, minimum.
3. Test duration, 1000 hours, except as permitted by Method 1005 of Mil-Std-883.
TABLE 2. ELECTRICAL TEST REQUIREMENTS
Mil-Std-883 Test Requirements Subgroups
per Method 5005, Table 1
Interim Electric Parameters
Method 5004
1
Final Electrical Parameters
Method 5005
1*, 2, 3, 9, 10, 11
Group A Test Requirements
Method 5005
1, 2, 3, 9, 10, 11
Group C and D End-Point Electrical Parameters
Method 5005
1
* PDA applies to Subgroup 1 only.
---------------------- Electrical Characteristics of MAX690/691/692/693/694 19-2553 Rev. C
------ /695/883B for /883B and SMD 5962-90711 and 5962-90712 Page 7 of 8

MAX695MJE/883B

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Supervisory Circuits MPU Supervisor
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union