RAC06-09SC

POWERLINE
AC/DC-Converter
with 3 year Warranty
RAC06-C
6 Watt
Single/Dual
Output
Very Compact AC-DC Power Supply
6 Watt PCB Mount Package
Single and Dual Output Versions
Universal Input Voltage Range
Class II Power Supply with 3kVAC Isolation
Low Output Ripple and Noise
Short Circuit, Overload, Overtemp Protected
Low Standby Power Consumption
UL/cUL Certified, CE Marked
Features
Regulated
Converters
Selection Guide
Part Input Output Output Efficiency Max
Number Range Voltage Current Capacitive
(VAC) (VDC) (mA) (%) Load
(1+2)
RAC06-3.3SC* 80-264 3.3 1500 70 12000µF
RAC06-05SC* 80-264 5 1200 75 6800µF
RAC06-09SC* 80-264 9 667 77 2500µF
RAC06-12SC* 80-264 12 500 78 1500µF
RAC06-15SC* 80-264 15 400 79 750µF
RAC06-24SC* 80-264 24 250 79 330µF
RAC06-05DC* 80-264 ±5 ±600 75 ±3300µF
RAC06-12DC* 80-264 ±12 ±250 78 ±680µF
RAC06-15DC* 80-264 ±15 ±200 79 ±330µF
* add suffix /W for wired version
Input Voltage Range (with derating) 80-264VAC or 115-370VDC
Rated Power 6 Watts max.
Input Frequency Range (for AC Input) 47-440Hz
Input Current (full load) 115/230VAC 120mA / 78mA typ.
No Load Power Consumption 250mW max.
Inrush Current (<2ms) 115/230VAC 30A/60A max.
Holdup Time (Full Load) 115VAC 10ms typ.
Leakage Current 0.85mA max.
Output Voltage Accuracy (Full load) ±2% max.
Line Voltage Regulation (low line, high line at full load) ±0.3% typ.
Load Voltage Regulation ( 5% to 100% full load ) ±0.5% typ.
Output Ripple and Noise (20MHz BW) 3.3V Output 120mVp-p max.
(with 100nF across each output) All Others 150mVp-p max.
Operating Frequency (full load) 132kHz typ.
Minimum Load = 0% specifications valid for 5% minimum load only
RMS Isolation Voltage (input to output) 3kVAC / 1minute
Isolation Resistance (input to output) 1 GΩ min.
Isolation Capacitance (input to output) 1000pF typ.
Short Circuit Protection Hiccup, Automatic Restart
Overload Protection 115VAC/230VAC 115% ~ 145%
Output Overvoltage Protection Zener Diode Clamp
(set at 4.8V - 5.4V for 3.3V and others 110% - 135% of its Nominal Output Voltage)
Over Voltage Category OVC II
continued on next page
Description
125
75
50
25
0
100
Ambient Temperature Range (°C)
-25
0
55
60
70
75
85 95
Output Power (%)
Natural Convection
Compact, low cost, high efficiency, universal input switching AC/DC power
module for PCB or wired mounting with single or dual outputs.
CE marked and UL/cUL Certified.
EN-60950-1 Certified
UL-60950-1 Certified
RoHS
2011/65/EU
6/6
Specifications
(measured at TA 25°C, full load after warm-up)
E224736
Refer to Application Notes
Derating-Graph
(Ambient Temperature)
www.recom-power.com PA-33REV: 0/2015
2.54
1.2
ø
+0.2/0.1
2.54
1
2
3
4
10
15
(5)
6.1
45.72
15.65
16.40+0.25
-
-
88
15.65
AWG#22
10
stripped and tinned
1
2
4
3
10.16
Bottom View
50.9 (single)
53.5 (dual)
20.32
Top View
1.0
10.16
10.16
Standoffs = 0.75+0.25
Leave
Clear of
PCB
Traces
(5)
10.16
25.5 (single)
27.8 (dual)
12.75 (single)
13.90 (dual)
50.9 (single)
53.5 (dual)
RAC06
RAC06-S_DC
Series
POWERLINE
AC/DC-Converter
Specifications
(measured at TA 25°C, full load after warm-up)
Pin Connections
Pin # Single Out Dual Out
1 VAC in (N) VAC in (N)
2 VAC in (L) VAC in (L)
3 +VDC out +VDC out
4 -VDC out Com
5 No Pin -VDC out
Tolerance ± 0.5 mm
Recommended Footprint Details
PCB Mounting Version (Standard)
Wired Version (Suffix /W)
Wire Connections
Wire AWG#22 Single Out Dual Out
Blue 1015 VAC in (N) VAC in (N)
Brown 1015 VAC in (L) VAC in (L)
Red 1007 +VDC out +VDC out
Black 1007 -VDC out Com
Orange 1007 -VDC out
Package Style and Pinning
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
3.3V
5V
15V, 24V
9V, 12V
Operating Temperature Range
(3)
(free air convection, without derating) -25°C to +55°C
(free air convection, with derating) -25°C to +75°C
Storage Temperature Range -40°C to +100°C
Recommended External Input Fuse 1.5A Slow Blow
Humidity 95% RH max.
Case Material Plastic Case filled with Epoxy (UL94V-0)
Package Weight Single/Dual 35g/38g
Packing Quantity Single Output 10 pcs
Dual Output 9 pcs
/W Version 1 pc
Emissions CE EN 55022: 2006 + A1: 2007 / Class B
EMC EN 55024:1998 + A1:2001 + A2:2003
Harmonics EN 61000-3-2:2006 / Class A
Flicker EN 61000-3-3:1995 + A1:2001 +A2:2005
Immunity ESD IEC 61000-4-2 / Criterion B
RS IEC 61000-4-3 / Criterion A
EFT IEC 61000-4-4 / Criterion B
Surge IEC 61000-4-5 / Criterion B
CS IEC 61000-4-6 / Criterion A
PMF IEC 61000-4-8 / Criterion A
Voltage Variations IEC 61000-4-11 / Criteria B + C
MTBF (+25°C) using MIL-HDBK-217F >400 x 10
3
hours
(+65°C) >200 x 10
3
hours
Certifications:
UL General Safety Report: E224736 UL-60950-1, 2nd Edition
cUL Report: E224736 C22.2 No. 60950-1-07, 2nd Edition
EN General Safety Report: SPCLVD1211033-1 EN-60950-1:2006 + A12:2011
CE EN55022 Class B
Efficiency %
100
0
40%0% 100%
40
Efficiency / Load
60%
80%
20%
20
60
80
Total Output current (%)
±5V
±12V, ±15V
Single Output
Dual Output
Input Voltage Derating Graph
Load (%)
Input Voltage (VAC) Ta=25°C
Safe Operating Area
100%
90%
80%
70%
80
130 180
230
280
90V, 100%
80V, 80%
264V, 100%
Notes:
Note1: Measured @ 230VAC / 50Hz / Ta=25°C with constant resistant mode at full load.
Note2: If used @ 115VAC / 60Hz with full load, max. capacitive load is less, please contact RECOM for
detailed information.
Note3: Start up only is guaranteed at temperatures down to -25°C. Other specifications may not be met.
The product information and specifications are subject to change without prior notice. All products are designed for non-safety critical commercial and industrial applications.
The Buyer agrees to implement safeguards that anticipate the consequences of any failures that might cause harm, loss of life and/or damage property.
PA-34 www.recom-power.comREV: 0/2015

RAC06-09SC

Mfr. #:
Manufacturer:
RECOM Power
Description:
Switching Power Supplies CONV AC/DC 6W 90-264VIN 09VOUT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union