Pressure Sensors 240PC Series
High Pressure Gage, Vacuum Gage/Amplified
54
Honeywell1 Sensing and Control11-800-537-6945 USA1F1-815-235-6847 International11-800-737-3360 Canada
NULL AND SENSITIVITY
TEMPERATURE SHIFT
Amplified pressure sensors are 100%
tested to ensure that the maximum null
and sensitivity temperature shift does not
exceed the specification. The diagram il-
lustrates how null and sensitivity shift re-
lates to temperature. Note that the maxi-
mum shift occurs at temperature ex-
tremes. Therefore, if a sensor is not ex-
posed to the entire temperature range,
the maximum null and sensitivity shift will
actually be less than the value specified.
This diagram indicates the temperature
shift pertaining to a few listings. Maximum
null and sensitivity shift varies from listing
to listing.
ELECTRICAL CONNECTIONS
Voltage Excitation
NOTES
1. Terminals are labeled on the sensor.
2. Input and output share a common
ground.
3. R
L
must be greater than or equal to
3000 ohms.
INTERNAL CIRCUITRY
Null and Sensitivity Shift (%Span)
MOUNTING DIMENSIONS (For reference only)
Leadwires
1 - Red, Vs
2 - Black, Ground (−)
3 - Green, Output