MAX8535/MAX8536/MAX8585
ORing MOSFET Controllers with Fastest
Fault Isolation for Redundant Power Supplies
4 _______________________________________________________________________________________
ELECTRICAL CHARACTERISTICS
(V
CC
= 12V (MAX8535/MAX8535A/MAX8585), V
CC
= 5V (MAX8536), V
CS
= V
CC
- 0.1V, R
TIMER
= 25k, UVP = 2V, OVP = 1V, C
GATE
= 0.01µF, T
A
= -40°C to +85°C, unless otherwise noted.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX
UNITS
V
CC
SUPPLY
V
CC
= 14V (MAX8535/
MAX8535A/MAX8585)
4.5
V
CC
Supply Current
TIMER = 2.5V
V
CC
= 6V (MAX8536) 3
mA
V
CC
= 14V (MAX8535/
MAX8535A/MAX8585)
4.5
V
CC
Shutdown Current TIMER = 0V
V
CC
= 6V (MAX8536) 3
mA
MAX8535/MAX8535A/
MAX8585, charge pump on
814
MAX8536, charge pump on
3.0 5.5V
CC
Input Voltage
TIMER = 2.5V
MAX8535/MAX8535A/
MAX8585, charge pump off
17
V
CS Isolation
C S = m ax op er ati ng vol tag e, V
C C
= 0V , I( V
C C
)
-1 µA
(MAX8535/MAX8535A/MAX8585) rising
threshold
6.0 7.0
V
CC
Undervoltage Lockout V
CCOK
(MAX8536) rising threshold 2.5 2.9
V
Rising threshold 14 15
V
CC
Overvoltage Internal
Threshold
(MAX8535/
MAX8535A/
MAX8585)
Falling threshold
13.3 14.5
V
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= 12V (MAX8535/MAX8535A/MAX8585), V
CC
= 5V (MAX8536), V
CS
= V
CC
- 0.1V, R
TIMER
= 25k, UVP = 2V, OVP = 1V, C
GATE
= 0.01µF, T
A
= 0°C to +85°C, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX
TIMER = open (MAX8535/MAX8535A/
MAX8536)
524
Startup Reverse-Current Blank
Time
MAX8585 32
ms
Forward-Current Threshold Measured from V
CC
to CS 5 10 15 mV
OVERVOLTAGE PROTECTION
OVP rising
1.219 1.25 1.281
OVP Fault Threshold V
OVP
OVP falling
1.2
V
OVP
Bias Current 0.2 µA
UNDERVOLTAGE PROTECTION
UVP rising threshold
1.219 1.25 1.281
UVP Fault Voltage V
UVP
UVP falling threshold
1.119 1.15 1.181
V
UVP
Bias Current 0.4 µA
MAX8535/MAX8536/MAX8585
ORing MOSFET Controllers with Fastest
Fault Isolation for Redundant Power Supplies
_______________________________________________________________________________________ 5
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= 12V (MAX8535/MAX8535A/MAX8585), V
CC
= 5V (MAX8536), V
CS
= V
CC
- 0.1V, R
TIMER
= 25k, UVP = 2V, OVP = 1V, C
GATE
= 0.01µF, T
A
= -40°C to +85°C, unless otherwise noted.) (Note 1)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
CHARGE-PUMP VOLTAGE
Measured from V
GATE
to V
CC
, V
CC
= 3.3V
(MAX8536)
56
V
CC
= 5V (MAX8536) 5 6
Gate Voltage V
GATE
V
C C
= 12V ( M AX 8535/M AX 8535A/M AX 8585) 9 12
V
TIMER
TIMER Voltage
1.200 1.281
V
TIMER Maximum Source Current
V
TIMER
= 1.0V 80
120
µA
TIMER High-Input Current V
TIMER
= 1.5V 20 µA
MAX8535/MAX8535A/MAX8585 1.5 3.4
TIMER Maximum Frequency
Select Voltage Input Range
MAX8536 1.5
V
CC
- 0.6
V
TIMER Logic High V
IH
Charge pump enabled 1.1 V
TIMER Logic Low V
IL
Charge pump disabled 0.5 V
FAULT
Fault Output Low Voltage I
FAULT
= 0.5mA 0.8 V
Fault Sink Current FAULT = 0.8V 0.5 mA
FAULT = 18V (MAX8535/
MAX8535A/MAX8585)
5
Fault Leakage Current
FAULT = 6V (MAX8536) 5
µA
GATE
Gate On Threshold Measured from V
CC
to CS 0.3 0.5 V
I
TIMER
= 0µA (MAX8535/
MAX8535A/MAX8585)
35 65
V
GATE
=
V
CC
= 12V
I
TIMER
= 50µA (MAX8535/
MAX8535A/MAX8585)
15 36
I
TIMER
= 0µA (MAX8536) 17 33
Gate-Drive Current
V
GATE
=
V
CC
= 5V
I
TIMER
= 50µA (MAX8536) 8 16
µA
Gate Shutdown Delay
From fault sense to the start of gate voltage
falling, or from TIMER to the start of gate
voltage falling
300
ns
GATE = V
CC
+ 5V (MAX8535/MAX8536)
100 300
Gate Discharge Current
MAX8535A/MAX8585
200 400
mA
CURRENT SENSE
Measured from CS to V
CC
(MAX8535/MAX8535A/MAX8586)
20 40
Reverse-Current Threshold
MAX8585 -5 +5
mV
Forward-Current Threshold Measured from V
CC
to CS 5 15 mV
MAX8535/MAX8536/MAX8585
ORing MOSFET Controllers with Fastest
Fault Isolation for Redundant Power Supplies
6 _______________________________________________________________________________________
ELECTRICAL CHARACTERISTICS (continued)
(V
CC
= 12V (MAX8535/MAX8535A/MAX8585), V
CC
= 5V (MAX8536), V
CS
= V
CC
- 0.1V, R
TIMER
= 25k, UVP = 2V, OVP = 1V, C
GATE
= 0.01µF, T
A
= -40°C to +85°C, unless otherwise noted.) (Note 1)
Note 1: Specifications to -40°C are guaranteed by design and not production tested.
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
OVERVOLTAGE PROTECTION
OVP Fault Threshold V
OVP
OVP rising
1.20 1.281
V
OVP Bias Current 0.2 µA
UNDERVOLTAGE PROTECTION
UVP rising threshold
1.200 1.281
UVP Fault Voltage V
UVP
UVP falling threshold
1.10 1.19
V
UVP
Bias Current 0.4 µA