Characteristics:
P.T. — Pretravel; O.T. — Overtravel; D.T. — Differential Travel; O.P. — Operating Position
VX ORDER GUIDE
Catalog Listings Operating Force P.T. max O.T. min. D.T. max. O.P.
Lever
Accepts Actuation
AMP Ounces Point Lever mm mm mm mm
Conn. Newtons (D) Style* inches inches inches inches
VX10 .35 + .18 (–.14)
0,1 (+,05,–,04) — —
2,16 1,02 0,30 14,73 ± 0,51
VX80 3.0 ± .88 —
(Pin Plunger) .085 .040 .012 .580 ± .020
0,83 ± ,24
VX10-A1 .35 ± .2
0,1 ± ,06
21,8 A 2,59 1,02 0,36 15,37 ± 0,69
VX80-A1 2.8± 1.1
.860 (Short) .102 .040 .014 .605 ± .027
,78 ± ,31
VX10-A2 0.2 ± .1
,06 ± ,03
35,6 A 5,33 2,16 0,71 15,34 ± 1,40
VX80-A2 1.41 ± .50
1.400 (Medium) .210 .085 .028 .604 ± .055
,39 ± ,14
VX10-A3 .10 ± .07
,03 ± ,02
59,4 A 9,96 4,06 1,32 15,24 ± 2,64
VX80-A3 .75 + .35 (–.25)
2.340 (Long) .392 .160 .052 .600 ± .104
,21 (+0,1–,07)
VX10-B1 0.20 + .15 (–.10)
,06 (+,04–,03)
32,6 B 5,21 1,91 0,64 18,52 ± 1,47
VX80-B1 1.55 ± .53
1.285 (Simulated Roller) .205 .075 .025 .729 ± .058
,43 ± ,15
VX10-C1 .40 ± .20
,11 ± ,06
20,6 C 2,49 1,02 0,33 20,68 ± 0,69
VX80-C1 3.0 ± 1.06
.810 (Short Roller) .098 .040 .013 .814 ± .027
,83 ± ,29
* Other lever styles are available. Contact MICRO SWITCH sales office.
Termination
Terminal pins accept AMP connectors
(not furnished):
AMP 102241-1
MICRO SWITCH part number:
VX1A — connector & receptacle
unassembled.
VX1A-01 — connector & receptacle
pre-assembled with 5.4N , 24 gauge
lead wires.
NOTE: The output transistors of the list-
ings shown are
‘‘
normally off.’’ They are
not conducting and the output voltage is
High with plunger in free position. To or-
der devices which are
‘‘
normally on’’ and
the output voltage is Low (conducting
with plunger in free position), change the
second digit from 0 to a 1, ora2toa3in
the catalog listing.
Example: VX10-A1 — VX11-A1